MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/a-2811-9609

Медицинская библиотека · RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin · 2026

3D bone reconstruction of the pelvis and hip through segmentation of tin-filtered ultra-low-dose CT compared with standard CT - a feasibility study.

Falkowski Anna L, Carrillo Fabio, Novina Danijel, Stern Christoph, Wichtmann Hildegard, Zingg Patrick O, Fürnstahl Philipp, Sutter Reto

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: 3D bone surface model reconstructions of CT exams are used for surgical planning. However, the accuracy of these models in tin-filtered ultra-low-dose CT examinations is unknown. Thus, we evaluated the accuracy of 3D-reconstructed bone models obtained from tin-filtered ultra-low-dose CT (tfCT) compared to standard CT (sCT) and calculated the radiation dose reduction.

MATERIALS AND

METHODS

IRB-approved prospective study with informed consent. Patients undergoing a pelvic sCT examination were scanned additionally with tfCT. 3D surface model reconstructions (left and right hemipelvis, and left and right proximal femur) of both scans were created, for each patient independently by two readers. The average error between the surface models of both methods was obtained using root mean square error (RMSE). The dose parameters that were used were volume CT dose index (CTDIvol) and dose length product (DLP). Radiation dose differences of both scans were evaluated using the Wilcoxon signed-rank test.

RESULTS

23 subjects (9 males and 14 females; mean age 31±8 years) were included. The mean RMSE was 0.47-0.48 mm for the right hemipelvis (left hemipelvis: 0.48-0.5 mm) and 0.52-0.56 for the proximal right femur (left femur: 0.5-0.57 mm). The average CTDIvol was 8.19±4.45 mGy for sCT examinations and 1.09±0.02 mGy for tfCT exams. The mean DLP was 220.45±124.36 mGy*cm for sCT examinations, and 29.12±1.54 mGy*cm for tfCT exams. The average CTDIvol and DLP were substantially lower (-87%) for tfCT compared to sCT (p<0.001).

CONCLUSION

3D surface model reconstruction from tfCT is feasible and has similar accuracy to that of sCT but with a substantially lower radiation dose.

KEY POINTS: · Pelvic 3D bone surface model reconstructions are feasible with tin-filtered ultra-low-dose CT.. · Reconstructions from tin-filtered ultra-low-dose CT have a similar accuracy as standard CT.. · Tin-filtered ultra-low-dose CT has a significantly lower radiation dose than standard CT..

CITATION FORMAT: · Falkowski AL, Carrillo F, Novina D et al. 3D bone reconstruction of the pelvis and hip through segmentation of tin-filtered ultra-low-dose CT compared with standard CT - a feasibility study. Rofo 2026; DOI 10.1055/a-2811-9609.

Для цитирования: Falkowski Anna L, Carrillo Fabio, Novina Danijel, Stern Christoph, Wichtmann Hildegard, Zingg Patrick O, Fürnstahl Philipp, Sutter Reto. 3D bone reconstruction of the pelvis and hip through segmentation of tin-filtered ultra-low-dose CT compared with standard CT - a feasibility study.. RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin. 2026. DOI: 10.1055/a-2811-9609.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.