MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/jpm16020124

Медицинская библиотека · Journal of personalized medicine · 2026

Implementation of an Intraoperative Augmented Reality Environment for Custom-Made Partial Pelvis Replacements-A Proof of Concept and Initial Results.

Hanusrichter Yannik, Gebert Carsten, Frieler Sven, Dudda Marcel, Streitbuerger Arne, Hardes Jendrik, Jeys Lee, Wessling Martin

СтатьяПеревод пока не подготовлен

Аннотация

Background

The use of augmented reality (AR) in orthopaedics is growing rapidly but is mainly limited to pre-operative planning and teaching. This study is one of the first to describe the intraoperative application within revision arthroplasty for the positioning of customised partial pelvic replacements.

Methods

In a proof-of-concept study an AR environment was used during surgery in 11 cases to enhance implant positioning. Postoperatively, a voxel-based CT deviation analysis was carried out to determine the COR deviation and the cup plane deviation angle. Additionally, digital implant superimposition was conducted.

Results

Implantation was possible in all cases with a mean COR deviation vector of 4.2 (SD 2.5; 1.2-9.3) mm and a cup plane deviation angle of 4.4 (SD 2.5; 0.7-8.1)°. The implant analysis showed a superimposition of 0.69 (SD 0.15; 0.38-0.88) (Dice-Score calculation).

Conclusions

This study is able to report promising results for AR in orthopaedic surgery, showing improved intraoperative feedback in complex operations, resulting in increased accuracy. However, the integration of AR poses a new challenge to the surgical team, especially because the AR users are facing a significantly increased level of intraoperative stress. Further development of this auspicious tool, as well as a conceivable combination with navigation, is necessary to facilitate broader usage.

Для цитирования: Hanusrichter Yannik, Gebert Carsten, Frieler Sven, Dudda Marcel, Streitbuerger Arne, Hardes Jendrik, Jeys Lee, Wessling Martin. Implementation of an Intraoperative Augmented Reality Environment for Custom-Made Partial Pelvis Replacements-A Proof of Concept and Initial Results.. Journal of personalized medicine. 2026. DOI: 10.3390/jpm16020124.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.