Psychosomatics · 2008
Electroconvulsive therapy in a candidate for heart transplant with an implantable cardiovertor defibrillator and cardiac contractility modulator.
Клинический случайСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Lynch Alison M, Pandurangi Ananda K, Levenson James L
Аннотация
BACKGROUND: Electroconvulsive therapy (ECT) can be life-saving in treating depression, even for high-risk cardiac patients. A 56-year-old man with type 2 diabetes and dilated cardiomyopathy, using both a defibrillator and an experimental cardiac contractility modulator, had had episodes of severe depression superimposed on dysthymia for 27 years, with a current exacerbation over the past 2 years, and little response to antidepressant treatment.
METHOD: He received a course of 12 ECTs (6 right-unilateral and 6 left-anterior/right-temporal electrode placements).
RESULTS: After these, he was judged moderately but not dramatically improved.
DISCUSSION: Serious adverse events, such as myocardial infarction, lethal arrhythmias, and cardiac rupture are possible in these high-risk patients, especially those with ejection fractions <50%, previous myocardial infarction, or significant arrhythmias. This case illustrates the complex decision-making involved and the need for close interdisciplinary collaboration entailed in preparing a high-risk patient with an implanted device for ECT.
METHOD: He received a course of 12 ECTs (6 right-unilateral and 6 left-anterior/right-temporal electrode placements).
RESULTS: After these, he was judged moderately but not dramatically improved.
DISCUSSION: Serious adverse events, such as myocardial infarction, lethal arrhythmias, and cardiac rupture are possible in these high-risk patients, especially those with ejection fractions <50%, previous myocardial infarction, or significant arrhythmias. This case illustrates the complex decision-making involved and the need for close interdisciplinary collaboration entailed in preparing a high-risk patient with an implanted device for ECT.