Anesthesia and analgesia · 2012
Minute-to-minute urine flow rate variability: a new renal physiology variable.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Klein Yoram, Grinstein Mor, Cohn Stephen M, Silverman Jacob, Klein Moti, Kashtan Hanoch, Shamir Micha Y
Аннотация
BACKGROUND: Urine output is a surrogate for tissue perfusion and is typically measured at 1-hour intervals. Because small urine volumes are difficult to measure in urine collection bags, considerable over- or underestimation is common. To overcome these shortcomings, digital urine meters were developed. Because these monitors measure urine volume in 1-minute intervals, they provide minute-to-minute measurements of the urine flow rate (UFR). In a previous study, we observed that the minute-to-minute variability in the UFR disappeared during hypovolemia. The aim of this study was to describe the minute-to-minute variability in the UFR as a new physiological variable and to show its relationship to blood volume depletion.
METHODS: Seven adult pigs were used in this study. The UFR, minute-to-minute UFR, mean arterial blood pressure, heart rate, and base excess were measured at euvolemia and during gradual hemorrhaging (10%, 20%, and 30% of estimated blood volume). Variance and wavelet spectral analysis were used to measure the disappearance of the minute-to-minute UFR variability.
RESULTS: The UFR decreased from 2.2 ± 0.2 to 1.0 ± 0.1 mL/min after a 10% estimated blood volume loss (±1 SE, n = 7, P = 0.0348). The variance in the minute-to-minute UFR decreased from 1.4 ± 0.3 to 0.4 ± 0.1 mL/min (±1 SE, n = 7, P = 0.046).
CONCLUSIONS: The UFR and its minute-to-minute variability decrease during hemorrhaging. The variability in the UFR may be useful as an aid for the diagnosis of hypovolemia.
METHODS: Seven adult pigs were used in this study. The UFR, minute-to-minute UFR, mean arterial blood pressure, heart rate, and base excess were measured at euvolemia and during gradual hemorrhaging (10%, 20%, and 30% of estimated blood volume). Variance and wavelet spectral analysis were used to measure the disappearance of the minute-to-minute UFR variability.
RESULTS: The UFR decreased from 2.2 ± 0.2 to 1.0 ± 0.1 mL/min after a 10% estimated blood volume loss (±1 SE, n = 7, P = 0.0348). The variance in the minute-to-minute UFR decreased from 1.4 ± 0.3 to 0.4 ± 0.1 mL/min (±1 SE, n = 7, P = 0.046).
CONCLUSIONS: The UFR and its minute-to-minute variability decrease during hemorrhaging. The variability in the UFR may be useful as an aid for the diagnosis of hypovolemia.