MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2214/ajr.16.17684

Медицинская библиотека · AJR. American journal of roentgenology · 2017

Metal Artifact Reduction for Orthopedic Implants (O-MAR): Usefulness in CT Evaluation of Reverse Total Shoulder Arthroplasty.

Shim Euddeum, Kang Yusuhn, Ahn Joong Mo, Lee Eugene, Lee Joon Woo, Oh Joo Han, Kang Heung Sik

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

The objective of this study is to evaluate the effect of the metal artifact reduction algorithm for orthopedic implants (O-MAR) on CT image quality for patients with reverse total shoulder arthroplasty (RTSA), with emphasis placed on the evaluation of bone in the vicinity of prostheses.

MATERIALS AND

METHODS

Sixty-five patients who underwent CT scanning after RTSA were enrolled in the study. Two radiologists analyzed the images reconstructed with filtered back projection (FBP) with or without O-MAR processing. Images were evaluated to determine the degree of streaking artifacts, the confidence in depicting various structures around the prosthesis, and the presence of pseudolesions. The mean CT number and SD of the selected ROIs placed in the greater tuberosity, glenoid bone, and deltoid muscle were recorded. For measurements from the greater tuberosity and glenoid bone, the frequency with which the measurement met the typical CT number of bone was calculated.

RESULTS

O-MAR images showed less metal streak artifact and noise and provided better visualization of the axillary neurovascular bundle compared with FBP images, with a statistically significant difference (p < 0.001 for all). FBP images were found to be statistically significantly better than O-MAR images, offering better visualization of bone cortex, bone trabeculae, and the bone-prosthesis interface (p < 0.001 for all). Scapular pseudonotching was observed on 4.6% of FBP images and 36.9% of O-MAR images. The pseudocemented appearance was noted on 47.7% of O-MAR images but was not seen on FBP images.

CONCLUSION

The use of O-MAR improved CT image quality for patients with RTSA in the aspect of metal artifact reduction and soft-tissue profile. However, O-MAR tends to degrade depiction of the bone trabeculae and bone cortex and generate new artifacts, including a pseudocemented appearance and scapular pseudonotching.

Для цитирования: Shim Euddeum, Kang Yusuhn, Ahn Joong Mo, Lee Eugene, Lee Joon Woo, Oh Joo Han, Kang Heung Sik. Metal Artifact Reduction for Orthopedic Implants (O-MAR): Usefulness in CT Evaluation of Reverse Total Shoulder Arthroplasty.. AJR. American journal of roentgenology. 2017. DOI: 10.2214/ajr.16.17684.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.