DOI 10.1007/s10792-021-02150-z
Randomized contralateral comparison of visual outcomes following implantation of two monofocal aspherical intraocular lenses after cataract surgery.
Аннотация
PURPOSE: To compare optical and visual performances of two one-piece aspherical implanted intraocular lenses (IOLs) following phacoemulsification cataract surgery in a contralateral eye study.
METHODS
In this prospective randomized parallel-group study, 25 patients with bilateral age-related cataract were implanted in one eye with the EnVista IOL (MX60, Bausch & Lomb Corporations, Rochester, NY, USA) and the Acrysof IQ IOL (Acrysof IQ SN60WF, Alcon Surgical Laboratories, Fort Worth, TX, USA) in the other eye. Uncorrected and corrected distance visual acuity (UDVA, CDVA), refractive status, higher-orders aberrations (HOAs) in 5 and 6 mm pupil size, contrast sensitivity (CS) with and without glare, color vision status, and patient satisfaction were assessed in the two eyes at 1 and 3 months after surgery.
RESULTS
There was no significant difference in CDVA (P > 0.99), UDVA (P = 0.46), spherical equivalent refractive error (P = 0.63), CS with and without glare across different spatial frequencies, color vision, and root mean square (RMS) of aberrometric values between the two IOLs after 3-month follow-up. Spherical aberration with 5 and 6 mm pupil sizes (P = 0.02) and horizontal coma with a 6 mm pupil size (P < 0.001) were lower with the EnVista IOL. Patient's satisfaction showed no cases of dissatisfaction, and most patients were highly or moderately satisfied with both IOLs.
CONCLUSION
The visual and optical performance of eyes implanted with the EnVista IOL or the Acrysof IQ IOL was similar, although the aberration profile differed.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.