Comparing the accuracy of new intraocular lens power calculation formulae in short eyes after cataract surgery: a systematic review and meta-analysis.

Luo Yu, Li Hongyu, Gao Lixiong, Du Jinlin, Chen Wenqian, Gao Yi, Ye Zi, Li Zhaohui

СтатьяМетаанализСистематический обзорПеревод пока не подготовлен

Аннотация

PURPOSE: Calculating the intraocular lens (IOL) power in short eyes for cataract surgery has been a challenge. A meta-analysis was conducted to identify, among several classic and new IOL power calculation formulae, which obtains the best accuracy.

METHODS

All studies aiming at comparing the accuracy of IOL power calculation formulae in short eyes were searched up in the databases of PubMed, EMBASE, Web of Science and the Cochrane library from Jan. 2011 to Mar. 2021. Primary outcomes were the percentages of eyes with a refractive prediction error in ± 0.25D, ± 0.5D and ± 1.0D.

RESULTS

Totally 1,476 eyes from 14 studies were enrolled in comparison of 13 formulae (Barrett Universal II, Castrop, Haigis, Hoffer Q, Holladay1, Holladay2, Kane, Ladas Super Formula, Okulix, Olsen, Pearl-DGS, SRK/T and T2). Pearl-DGS had the highest percentage within ± 0.25D. In the ± 0.5D range, Pearl-DGS obtained the highest percentage again, and it was significantly higher than Barrett Universal II, Haigis, Hoffer Q, Holladay1, Holladay2 and Olsen (P = 0.001, P = 0.02, P = 0.0003, P = 0.01, P = 0.007, P = 0.05, respectively). In the ± 1.0D range, Okulix possessed the highest percentage, and it was significantly higher than Barrett Universal II, Castrop, Hoffer Q and Holladay2 (P = 0.0005, P = 0.03, P = 0.003, P = 0.02, respectively).

CONCLUSION

The new generation formulae, based on artificial intelligence or ray-tracing principle, are more accurate than the convergence formulae. Pearl-DGS and Okulix are the two most accurate formulae in short eyes.

Для цитирования: Luo Yu, Li Hongyu, Gao Lixiong, Du Jinlin, Chen Wenqian, Gao Yi, Ye Zi, Li Zhaohui. Comparing the accuracy of new intraocular lens power calculation formulae in short eyes after cataract surgery: a systematic review and meta-analysis.. International ophthalmology. 2022. DOI: 10.1007/s10792-021-02191-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.