MedElevator Войти в исследования
← Поиск публикаций

DOI 10.31729/jnma.5130

Медицинская библиотека · JNMA; journal of the Nepal Medical Association · 2021

Study of Intraocular Pressure following Neodynium Yttrium Aluminium Garnet Laser Capsulotomy with the Use of Brimonidine: A Descriptive Cross-sectional Study.

Manandhar Laxmi Devi, Gurung Nanda, Shrestha Koshal, Bhattarai Binita, Godar Manita, Shrestha Rahul

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

Posterior capsular opacification is a common complication after cataract surgery. Neodynium Yttrium Aluminium Garnet laser capsulotomy is still the preferred treatment for posterior capsular opacification. This study was done to determine the use of Brimonidine eye drop in preventing the rise of intraocular pressure post-Neodynium Yttrium Aluminium Garnet laser capsulotomy.

METHODS

A descriptive cross-sectional study was conducted in Lumbini eye institute and research center, Bhairahawa, Nepal, in 200 eyes with posterior capsular opacification using Brimonidine from Feb 1, 2019, to July 30, 2019. The Institutional Review Committee approved the study with approval number 0237. A convenient sampling method was used. Pre-capsulotomy best-corrected visual acuity, slit-lamp examination of the anterior segment, and dilated fundus examination were done. Intraocular pressure was measured with Goldmann Applanation Tonometer. Post capsulotomy patients were evaluated after one hour, two hours, and two weeks for intraocular pressure and any complications. The statistical analysis was done using Statistical Package of Social Sciences version 20.0 statistical analysis software. The descriptive statistical analysis of the study was done after the collection of the data.

RESULTS

Mean age of patients at presentation was 61.61±SD 1.09. The mean intraocular pressure following Neodynium Yttrium aluminum garnet laser capsulotomy using brimonidine at 1 hour was 12.73±3.3 mmHg.and two hours was 11.98±3.2 mmHg. The mean energy per pulse was 2.3±SD 0.3 mJ. The mean duration of posterior capsular opacification from cataract surgery was 22.28 weeks.

CONCLUSIONS

Neodynium Yttrium Aluminium Garnet laser capsulotomy had lower intraocular pressure after the Brimonidine eye drop procedure. The maximum mean reduction in intraocular pressure was observed after two hours.

Для цитирования: Manandhar Laxmi Devi, Gurung Nanda, Shrestha Koshal, Bhattarai Binita, Godar Manita, Shrestha Rahul. Study of Intraocular Pressure following Neodynium Yttrium Aluminium Garnet Laser Capsulotomy with the Use of Brimonidine: A Descriptive Cross-sectional Study.. JNMA; journal of the Nepal Medical Association. 2021. DOI: 10.31729/jnma.5130.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.