MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00417-021-05309-7

Медицинская библиотека · Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2021

Intraocular lens power calculation using adjusted corneal power in eyes with prior myopic laser vision correction.

Huh Jungah, Eom Youngsub, Yoon Eun Gyu, Kim Jun-Heon, Song Jong Suk, Kim Hyo Myung

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the prediction accuracy of the intraocular lens (IOL) power calculation using adjusted corneal power according to the posterior/anterior corneal curvature radii ratio in the Haigis formula (Haigis-E) in patients with a history of prior myopic laser vision correction.

METHODS

Seventy eyes from 70 cataract patients who underwent cataract surgery and had a history of myopic laser vision correction were enrolled. The adjusted corneal power obtained with conventional keratometry (K) was calculated using the posterior/anterior corneal curvature radii ratio measured by a single Scheimpflug camera. In eyes longer than 25.0 mm, half of the Wang-Koch (WK) adjustment was applied. The median absolute error (MedAE) and the percentage of eyes that achieved a postoperative refractive prediction error within ± 0.50 diopters (D) based on the Haigis-E method was compared with those in the Shammas, Haigis-L, and Barrett True-K no-history methods.

RESULTS

The MedAE predicted using the Haigis-E (0.33 D) was significantly smaller than that obtained using the Shammas (0.44 D), Haigis-L (0.43 D), and Barrett True-K (0.44 D) methods (P < 0.001, P = 0.001, and P = 0.014, respectively). The percentage of eyes within ± 0.50 D of refractive prediction error using the Haigis-E (78.6%) was significantly greater than that produced using the Shammas (57.1%), Haigis-L (58.6%), and Barrett True-K (61.4%) methods (P = 0.025).

CONCLUSION

IOL power calculation using the adjusted corneal power according to the posterior/anterior corneal curvature radii ratio and modified WK adjustment in the Haigis formula could improve the refraction prediction accuracy after cataract surgery in eyes with prior myopic laser vision correction.

Для цитирования: Huh Jungah, Eom Youngsub, Yoon Eun Gyu, Kim Jun-Heon, Song Jong Suk, Kim Hyo Myung. Intraocular lens power calculation using adjusted corneal power in eyes with prior myopic laser vision correction.. Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie. 2021. DOI: 10.1007/s00417-021-05309-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.