MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0251152

Медицинская библиотека · PloS one · 2021

Refractive prediction of four different intraocular lens calculation formulas compared between new swept source optical coherence tomography and partial coherence interferometry.

Song Mi Yeon, Noh Sung Rae, Kim Kook Young

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To compare the biometry and prediction of postoperative refractive outcomes of four different formulae (Haigis, SRK/T, Holladay1, Barrett Universal II) obtained by swept-source optical coherence tomography (SS-OCT) biometers and partial coherence interferometry (PCI; IOLMaster ver 5.4).

METHODS

We compared the biometric values of SS-OCT (ANTERION, Heidelberg Engineering Inc., Heidelberg, Germany) and PCI (IOLMaster, Carl Zeiss Meditec, Jena, Germany). Predictive errors calculated using four different formulae (Haigis, SRKT, Holladay1, Barrett Universal II) were compared at 1 month after cataract surgery.

RESULTS

The mean preoperative axial length (AL) showed no statistically significant difference between SS-OCT and PCI (SS-OCT: 23.78 ± 0.12 mm and PCI: 23.77 ± 0.12 mm). The mean anterior chamber depth (ACD) was 3.30 ± 0.04 mm for SS-OCT and 3.23 ± 0.04 mm for PCI, which was significantly different between the two techniques. The mean corneal curvature also differed significantly between the two techniques. The difference in mean arithmetic prediction error was significant in the Haigis, SRKT, and Holladay1 formulae. The difference in mean absolute prediction error was significant in all four formulae.

CONCLUSIONS

SS-OCT and PCI demonstrated good agreement on biometric measurements; however, there were significant differences in some biometric values. These differences in some ocular biometrics can cause a difference in refractive error after cataract surgery. New type SS-OCT was not superior to the IOL power prediction calculated by PCI.

Для цитирования: Song Mi Yeon, Noh Sung Rae, Kim Kook Young. Refractive prediction of four different intraocular lens calculation formulas compared between new swept source optical coherence tomography and partial coherence interferometry.. PloS one. 2021. DOI: 10.1371/journal.pone.0251152.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.