MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1155/2021/6695454

Медицинская библиотека · Journal of ophthalmology · 2021

Three-Random-Point Marking Method for Toric Intraocular Lens Alignment Using the iTrace Aberrometer.

Niu Yongyi, Lin Hongliang, Qin Yongjie, Yang Cheng, Chen Yanlei, Zeng Jin, Zhang Hongyang

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the clinical outcome of the three-random-point (TRP) marking method for toric intraocular lens (IOL) alignment using the iTrace aberrometer (Tracey Technologies Corp., Houston, TX). Setting. Department of Ophthalmology, Guangdong Eye Institute, Guangdong Academy of Medical Sciences, Guangdong Provincial People's Hospital, Guangzhou, China.

DESIGN

Prospective, randomized comparative trial.

METHOD: Thirty eyes of 30 patients undergoing cataract surgery with coexisting corneal astigmatism of over 1.0 D were included in this study. All patients were prospectively randomized into the TRP marking group or slit-lamp horizontal meridian (SHM) marking group. TRP marking involved marking three points randomly in the corneal limbus of the patients and accurately marking the horizontal meridian was not required. The follow-up duration was 3 months after cataract surgery.

RESULTS

Fifteen eyes of 15 patients were in the TRP marking group and 15 eyes of 15 patients in the SHM marking group. There was no statistically significant difference in BCVA, UDVA, preexisting corneal astigmatism, or residual astigmatism between the groups before or after surgery (P > 0.05). The mean toric IOL misalignment was lesser but without significance in the TRP marking group than in the SHM marking group after 3 postoperative months (2.66° ± 1.42° versus 3.29° ± 1.67°; P=0.295).

CONCLUSION

The TRP marking method using the iTrace aberrometer is simple and accurate for preoperative marking of toric IOLs. It can eliminate the potential systematic errors resulting from varying head positions during the preoperative keratometry measurement and from manual marking.

Для цитирования: Niu Yongyi, Lin Hongliang, Qin Yongjie, Yang Cheng, Chen Yanlei, Zeng Jin, Zhang Hongyang. Three-Random-Point Marking Method for Toric Intraocular Lens Alignment Using the iTrace Aberrometer.. Journal of ophthalmology. 2021. DOI: 10.1155/2021/6695454.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.