MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcrs.2014.11.011

Медицинская библиотека · Journal of cataract and refractive surgery · 2015

Comparison of vault after implantation of posterior chamber phakic intraocular lens with and without a central hole.

Kamiya Kazutaka, Shimizu Kimiya, Ando Wakako, Igarashi Akihito, Iijima Kei, Koh Ayaka

Сравнительное исследованиеСтатьяНаблюдательное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To compare the vault after implantation of a posterior chamber phakic intraocular lens (pIOL) (Visian Implantable Collamer Lens) with and without a central artificial hole for moderate to high ametropia.

SETTING

Department of Ophthalmology, Kitasato University, Kanagawa, Japan.

DESIGN

Retrospective comparative study.

METHODS

The study comprised eyes of patients who had central hole pIOL implantation in 1 eye and conventional pIOL implantation in the fellow eye. The time course of the postoperative pIOL vault was quantitatively assessed using a rotating Scheimpflug camera (Pentacam HR).

RESULTS

Twenty-three patients (46 eyes) (mean age 31.3 years ± 7.4 [SD]) were enrolled in the study. The amount of vault with the central hole pIOL was 603 ± 276 μm, 552 ± 261 μm, 539 ± 258 μm, 520 ± 240 μm, and 482 ± 245 μm, at 1 week, 1 month, 3 months, 6 months, and 1 year postoperatively, respectively. The amount with the conventional pIOL vault was 585 ± 252 μm, 550 ± 269 μm, 514 ± 253 μm, 485 ± 233 μm, and 459 ± 239 μm, respectively. There was no significant association between the pIOL vault and the refractive accuracy 1 year postoperatively (Spearman correlation coefficient r = 0.18, P = 0.41 for central hole pIOL and r = 0.07, P = .76 for conventional pIOL).

CONCLUSIONS

The vault of the new central hole pIOL appeared to be essentially equivalent to the vault of the conventional pIOL, suggesting that the presence of the central hole did not significantly affect the vault or the refractive accuracy.

FINANCIAL DISCLOSURE: Dr. Shimizu is a consultant to Staar Surgical Co. and has assisted with the development of patented technologies. No other author has a financial or proprietary interest in any material or method mentioned.

Для цитирования: Kamiya Kazutaka, Shimizu Kimiya, Ando Wakako, Igarashi Akihito, Iijima Kei, Koh Ayaka. Comparison of vault after implantation of posterior chamber phakic intraocular lens with and without a central hole.. Journal of cataract and refractive surgery. 2015. DOI: 10.1016/j.jcrs.2014.11.011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.