Decentration of 5.1 mm intraocular lenses after continuous curvilinear capsulorhexis and in-the-bag fixation.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Patel C K, Rosen P, Brown N A, Bron A J
Аннотация
PURPOSE: To determine the incidence of decentration in eyes with 5.1 mm optic intraocular lenses (IOLs) and to assess the effect on vision.
SETTING: Clinical Cataract Research Unit, Oxford Eye Hospital, Oxford, England.
METHODS: Patients having phacoemulsification and small IOL implantation over 12 months were identified and invited for assessment. Intraocular lens decentration was measured geometrically using a modified, digital, retroillumination camera. The expected incidence of symptoms caused by decentration was estimated by determining the presence of an IOL edge within an artificial pupil overlaid on the digital image.
RESULTS: In 13 eyes (20%), IOL decentration was more than 0.5 mm. Symptoms were expected in 38 patients (59%) but occurred in only 14 (22%).
CONCLUSION: Decentration of the 5.1 mm optic IOL caused fewer clinical problems than anticipated, although the results raise concerns that such IOLs may be inappropriate in patients who need excellent vision in scotopic illumination.
SETTING: Clinical Cataract Research Unit, Oxford Eye Hospital, Oxford, England.
METHODS: Patients having phacoemulsification and small IOL implantation over 12 months were identified and invited for assessment. Intraocular lens decentration was measured geometrically using a modified, digital, retroillumination camera. The expected incidence of symptoms caused by decentration was estimated by determining the presence of an IOL edge within an artificial pupil overlaid on the digital image.
RESULTS: In 13 eyes (20%), IOL decentration was more than 0.5 mm. Symptoms were expected in 38 patients (59%) but occurred in only 14 (22%).
CONCLUSION: Decentration of the 5.1 mm optic IOL caused fewer clinical problems than anticipated, although the results raise concerns that such IOLs may be inappropriate in patients who need excellent vision in scotopic illumination.