Comparison of simultaneous prism and cover test (SPCT) and prism and alternate cover test (PACT) measurements with final power of Press-On prism power dispensed.

Christoff Alex

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To investigate the association of strabismic angle obtained by simultaneous prism and cover test (SPCT) and prism alternate cover test (PACT) with the final power of Press-On prism used in adults with symptomatic strabismus.

METHODS

The medical records of consecutive patients seen by a single orthoptist at an urban, tertiary care hospital over a 36-month period were reviewed retrospectively. All subjects had been prescribed Press-On prism for diplopia after evaluation with SPCT and PACT measurements at distance fixation. Prism dispensed was chosen by the patient using a trial Press-On prism set.

RESULTS

A total of 244 charts were reviewed. Of these, 108 adult patients had prism dispensed, and 32 had both SPCT and PACT measurements. Mean SPCT measurement was 7Δ (median, 6Δ; range, 3Δ-14Δ); mean PACT, 13Δ (median, 11Δ; range, 8Δ-20Δ). The mean prism power dispensed was 7Δ (median, 6Δ; range, 1Δ-15Δ); this was not significantly different from mean SPCT (P = 0.35). There was a large difference (6Δ) between mean PACT measurements and mean prism dispensed (P < 0.001). At follow-up of 1 year, 21 patients (66%) remained in prism. Nine patients (4%) elected to undergo eye muscle surgery, 7 with horizontal strabismus, 6 of whom had SPCT measurements of >10Δ and PACT measurements of >15Δ.

CONCLUSIONS

Press-On prism power used was more closely tied to the angle of strabismus obtained by SPCT. Overall success rate of Press-On prism was good when the prism power dispensed was close to the SPCT measurement, suggesting that it is reasonable to initiate treatment with a weaker prism, approximating the SPCT measurement, building up only if there are continuing symptoms.

Для цитирования: Christoff Alex. Comparison of simultaneous prism and cover test (SPCT) and prism and alternate cover test (PACT) measurements with final power of Press-On prism power dispensed.. Journal of AAPOS : the official publication of the American Association for Pediatric Ophthalmology and Strabismus. 2024. DOI: 10.1016/j.jaapos.2024.103918.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.