Subarachnoid hemorrhage: aneurysm detection and preoperative evaluation with CT angiography.

Velthuis B K, Rinkel G J, Ramos L M, Witkamp T D, Berkelbach van der Sprenkel J W, Vandertop W P, van Leeuwen M S

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate if computed tomographic (CT) angiography can replace digital subtraction angiography (DSA) for aneurysm detection and as preoperative work-up in patients with subarachnoid hemorrhage (SAH).

MATERIALS AND

METHODS

Prospectively, 100 patients with SAH underwent CT angiography; 80 also underwent DSA. Two observers independently evaluated CT angiographic source images and maximum intensity projection slabs. Neurosurgeons compared CT angiograms and DSA images for presurgical evaluation.

RESULTS

On CT angiograms, the observers detected 73 and 70 of 75 symptomatic aneurysms; 96% of the detected aneurysms were classified as definitely present. Of 16 incidental aneurysms, 12 and 10 were detected by the observers. With adequate CT angiographic quality, parent artery side of anterior communicating aneurysms was correctly predicted in 100% (95% confidence interval [CI]: 87%, 100%). Neurosurgeons assessed CT angiography as equal or superior to DSA in 83% (95% CI: 73%, 90%) of 87 aneurysms, and in 74% (95% CI: 63%, 82%) operation might have been based on CT angiographic findings alone.

CONCLUSION

CT angiography depicted 90% of all aneurysms, and 90% were classified as definitely present. CT angiography must be of high quality with adequate depiction of the aneurysm and the parent artery for surgery to be performed on the basis of CT angiographic findings alone.

Для цитирования: Velthuis B K, Rinkel G J, Ramos L M, Witkamp T D, Berkelbach van der Sprenkel J W, Vandertop W P, van Leeuwen M S. Subarachnoid hemorrhage: aneurysm detection and preoperative evaluation with CT angiography.. Radiology. 1998. DOI: 10.1148/radiology.208.2.9680571.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.