MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/ctr.70179

Медицинская библиотека · Clinical transplantation · 2025

Hyperfibrinolysis Detection During Liver Transplantation Using Viscoelastometry.

Thaler Sarah, Zorn Anna, Aster Isabell, Koliogiannis Dionysios, Renz Bernhard W, Guba Markus, Groene Philipp

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

End-stage liver disease induces a precarious hemostatic equilibrium, named rebalanced hemostasis. Liver transplantation additionally causes profound disturbances in the hemostatic balance. Hyperfibrinolysis poses a relevant impairment to the coagulation process during liver transplantation. During surgery, the hemostatic management is guided by viscoelastic monitoring systems. The aim of this prospective, observational study was to evaluate the incidence of hyperfibrinolysis during liver transplantation using different viscoelastic assays, namely an ecarin-based test and a tissue factor-based test.

METHODS

Blood sampling was done at five measurement time points during liver transplantation (T1 induction of general anesthesia, T2 start of anhepatic phase, T3 end of anhepatic phase, T4 10 min after reperfusion, T5 end of surgery). Viscoelastic testing included ClotPro assays EX-test, FIB-test, AP-test, and ECA-test. Hyperfibrinolysis was defined as a maximum lysis of at least 15%. Lysis detection time (LDT) served as an indicator for the velocity of lysis, marking the time point when less than 85% of the clot are extant.

RESULTS

Thirty transplantation surgeries were included. A total of 150 viscoelastic measurements have been performed. The ECA-test detected hyperfibrinolysis significantly more often (31 [21%] vs. 22 [15%] out of 150, p = 0.039) and in a higher number of patients than the EX-test. The ECA-test revealed hyperfibrinolysis significantly earlier compared to the EX-test (median LDT 2100 s [1500/2900] vs. 3300 s [2400/3800], p < 0.001).

CONCLUSION

This study demonstrates higher sensitivity of the ecarin-test than the tissue-factor-test in monitoring hyperfibrinolysis, with more frequent and earlier detection of this coagulopathy.

TRIAL REGISTRATION: German Clinical Trials Register: DRKS00032827.

Для цитирования: Thaler Sarah, Zorn Anna, Aster Isabell, Koliogiannis Dionysios, Renz Bernhard W, Guba Markus, Groene Philipp. Hyperfibrinolysis Detection During Liver Transplantation Using Viscoelastometry.. Clinical transplantation. 2025. DOI: 10.1111/ctr.70179.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.