MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0345582

Медицинская библиотека · PloS one · 2026

Comparable performance of 3D and 2D anterior segment optical coherence tomography in predicting intraocular pressure reduction following cataract surgery.

Chansangpetch Sunee, Phinyo Phichayut, Patumanond Jayanton, Choovuthayakorn Janejit, Lin Shan C

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To develop predictive models using three-dimensional (3D) and conventional two-dimensional (2D) anterior-segment optical coherence tomography (AS-OCT) parameters for intraocular pressure (IOP) reduction following phacoemulsification in glaucoma and non-glaucoma cohorts.

METHODS

This prospective study included patients with and without glaucoma who underwent phacoemulsification. Preoperative predictors of 1-month IOP reduction, including clinical, ocular biometry, and AS-OCT (CASIA2) parameters, were analyzed. 3D AS-OCT measurements were assessed in two approaches: (1) averaging 360-degree values and (2) estimating circumferential areas or volumes. 2D variables were obtained from horizontal cross-sectional images. Model selection with least absolute shrinkage and selection operator (LASSO) for 2D and 3D variables was performed separately. R-squared (R²) used to represent model accuracy. The performance was validated by bootstrap resampling.

RESULTS

A total of 130 eyes (64 glaucoma, 66 non-glaucoma) from 103 patients were included. The average IOP change was -1.20 ± 3.29 mmHg. Preoperative IOP (preIOP) was the strongest single predictor across all models. In the entire cohort, the final models showed moderate predictability (R² 38% for 3D and 36% for 2D; optimism-corrected R² 31% for both). In glaucoma eyes, models incorporating AS-OCT angle status and anterior chamber width achieved R² values of 36% (3D) and 38% (2D), with optimism-corrected R² of 27% (3D) and 28% (2D). In non-glaucoma eyes, both 3D and 2D models showed higher predictability (R² 53%, optimism-corrected R² 45%), with final predictors incorporating AS-OCT anterior chamber area and iris thickness. Both 3D and 2D models significantly outperformed the reference preIOP models across all cohorts (all p > 0.05).

CONCLUSIONS

AS-OCT parameters improved the predictability of IOP reduction after phacoemulsification, with notably better performance in non-glaucoma eyes. 2D and 3D models showed comparable predictive ability.

Для цитирования: Chansangpetch Sunee, Phinyo Phichayut, Patumanond Jayanton, Choovuthayakorn Janejit, Lin Shan C. Comparable performance of 3D and 2D anterior segment optical coherence tomography in predicting intraocular pressure reduction following cataract surgery.. PloS one. 2026. DOI: 10.1371/journal.pone.0345582.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.