MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/j.jcrs.0000000000001840

Медицинская библиотека · Journal of cataract and refractive surgery · 2026

Evaluation of spectacle independence with the Dutch Patient-Reported Spectacle Independence Questionnaire.

Reus Nicolaas J, van Dorst Fallon, Kooijman-de Groot Marjolein J C, Weenen Christien, Porro Giorgio L, Morlock Robert, Pesudovs Konrad

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate spectacle independence in healthy individuals and cataract patients with different types of intraocular lenses (IOLs) and refractive targets using a Dutch translation of The Patient-Reported Spectacle Independence Questionnaire (PRSIQ). The PRSIQ is a patient-reported outcome measure that assesses patient need for, wearing of, and functioning without spectacles for distance, intermediate, and near vision.

SETTING

Amphia Hospital, Breda, the Netherlands.

DESIGN

Prospective, observational, cross-sectional, single-center study.

METHODS

The English questionnaire was translated to Dutch following the ISPOR guidelines. 361 participants across various groups were included: healthy individuals aged younger than and older than 50 years and cataract patients with bilateral implantation of monofocal, enhanced monofocal, toric monofocal, monofocal with a myopic target, extended depth-of-focus (EDOF), or trifocal IOLs.

RESULTS

Dichotomous scoring showed significantly different rates of complete spectacle independence: 28 of 49 (57%) for trifocals, 8 of 47 (17%) for EDOFs, 2 of 44 (5%) for monofocals, 1 of 50 (2%) for enhanced monofocals, 0 of 25 (0%) for toric monofocals, 1 of 46 (2%) for myopic targets, and 10 of 50 (20%) and 1 of 50 (2%) for healthy participants younger than and older than 50 years. Participants with minimal refractive errors reported complete spectacle independence in 20 of 28 (71%) with trifocals and 5 of 21 (24%) with EDOF IOLs. Rasch analysis showed that the questionnaire was multidimensional and thus failed to support interval scaling.

CONCLUSIONS

The Dutch PRSIQ-NL demonstrated significant differences in self-reported complete spectacle independence across IOL types and refractive targets using dichotomous scoring. Rasch analysis showed PRSIQ-NL cannot be used for interval-scaled measurements. The PRSIQ-NL is valuable for clinical and research applications to evaluate spectacle independence using dichotomous scoring.

Для цитирования: Reus Nicolaas J, van Dorst Fallon, Kooijman-de Groot Marjolein J C, Weenen Christien, Porro Giorgio L, Morlock Robert, Pesudovs Konrad. Evaluation of spectacle independence with the Dutch Patient-Reported Spectacle Independence Questionnaire.. Journal of cataract and refractive surgery. 2026. DOI: 10.1097/j.jcrs.0000000000001840.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.