Precision in Intraocular Lens Calculation for Chinese Cataract Patients with Prior History of Radial Keratotomy.
Аннотация
PURPOSE: To evaluate the predictive accuracy of eight traditional and contemporary intraocular lens (IOL) power calculation formulas in Chinese cataract patients with prior radial keratotomy (RK).
PATIENTS AND
METHODS
RK patients who underwent phacoemulsification with IOL implantation were retrospectively recruited. Refractive prediction errors (RPE)were calculated for eight formulas: Haigis-L, Shammas, Barrett True-K, Camellin Calossi Camellin (CCC), Kane, EVO, Pearl-DGS, and Jin-AI. The study compared RPE, mean absolute error (MAE), median absolute error (MedAE), and percentages of eyes achieving prediction errors within ±0.25, ±0.50, ±0.75, ±1.0, and ±2.0 diopters.
RESULTS
This retrospective study analyzed 34 eyes from 21 patients with prior RK surgery. The superior performing IOL power calculation formulas were Jin-AI (MAE = 0.64 D, MedAE = 0.49 D), Barrett True-K (MAE = 0.58 D, MedAE = 0.535 D), and EVO (MAE=0.59 D, MedAE = 0.538 D). These three formulas demonstrated comparable accuracy, with 47.1%, 44.1%, and 44.1% of eyes achieving prediction errors within ±0.50 D, respectively. The Haigis-L and Pearl-DGS formulas exhibited significantly higher prediction errors in eyes with more than 12 RK incisions.
CONCLUSION
The Jin-AI, Barrett True-K, and EVO formulas demonstrated superior accuracy for IOL power calculation in Chinese cataract patients with prior RK. The Jin-AI formula, a novel artificial intelligence-based formula derived from Chinese individuals, presents a promising option for post-RK IOL calculation, while external validation studies across diverse ethnic groups are essential.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.