MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/j.jcrs.0000000000001929

Медицинская библиотека · Journal of cataract and refractive surgery · 2026

Refractive prediction error after intrascleral intraocular lens fixation in eyes with long axial length.

Suzue Masaki, Goto So, Sakimoto Susumu, Nakao Gen, Shiraki Akihiko, Nishida Kentaro, Maruyama Kazuichi, Sato Shigeru, Maeno Takatoshi, Nishida Kohji

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the refractive prediction accuracy of intraocular lens (IOL) power calculation formulas after flanged intrascleral IOL fixation (SF-IOL; Yamane technique) in long axial length (AL) eyes.

SETTING

University of Osaka Hospital, Osaka, Japan.

DESIGN

Retrospective observational cohort study.

METHODS

Eyes undergoing SF-IOL between January 2023 and April 2024 were classified into normal (N, <26.0 mm) and long (L, ≥26.0 mm) AL groups. Barrett Universal II, Hoffer Q, Holladay 1, and SRK/T were evaluated. Prediction error (PE) was defined as 3-month postoperative spherical equivalent minus predicted value. Prediction accuracy was assessed using root mean square absolute error (RMSAE) and the Formula Performance Index (FPI).

RESULTS

53 eyes from 50 patients were analyzed (N = 35; L = 18). Mean AL was 24.6 ± 0.8 mm (N) and 27.1 ± 1.0 mm (L). Mean PE (N and L) was -0.55 ± 0.72 diopters (D) and -0.64 ± 0.62 D with Barrett Universal II ( P = .52), -0.68 ± 0.77 D and -0.45 ± 0.62 D with Hoffer Q ( P = .32), -0.78 ± 0.74 D and -0.31 ± 0.72 D with Holladay 1 ( P = .043), and -0.74 ± 0.72 D and -0.62 ± 0.72 D with SRK/T ( P = .60). In the L group, Holladay 1 showed PE nearest zero; however, demonstrated steep AL-PE regression slope and low FPI. Barrett Universal II yielded the lowest RMSAE and the highest FPI.

CONCLUSIONS

Barrett Universal II demonstrated the highest overall predictive accuracy in long AL eyes undergoing SF-IOL. Although Holladay 1 produced a smaller PE in long AL, this reflected systematic offset rather than superior accuracy, as indicated by its lower FPI.

Для цитирования: Suzue Masaki, Goto So, Sakimoto Susumu, Nakao Gen, Shiraki Akihiko, Nishida Kentaro, Maruyama Kazuichi, Sato Shigeru, Maeno Takatoshi, Nishida Kohji. Refractive prediction error after intrascleral intraocular lens fixation in eyes with long axial length.. Journal of cataract and refractive surgery. 2026. DOI: 10.1097/j.jcrs.0000000000001929.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.