DOI 10.1186/s12885-025-13618-x
A comparative study of mitoxantrone hydrochloride injection and technetium-99 m for tracing axillary sentinel nodes in patients with breast cancer.
Аннотация
PURPOSE: An earlier multicenter phase III study demonstrated the safety and efficacy of mitoxantrone hydrochloride injection for tracing (MHI) for detecting sentinel lymph nodes (SLNs) in breast cancer patients. This ancillary study was conducted to further analyze and discover differences between the two tracers that had not been reported previously.
METHODS
This analysis used single-center data from a phase III trial. Patients with breast cancer were injected with both MHI and 99mTc as SLN tracers before surgery. To account for cluster effects of multiple SLNs from the same patient and further analyze the differences between the two methods and factors that could impact detection, Obuchowski's modified McNemar test, the GLIMMIX model, and univariate and multivariate analyses were used as appropriate.
RESULTS
In total, 463 SLNs from 109 patients were resected, 47 of which were pathologically positive. The SLN detection rate did not significantly differ between MHI and 99mTc. MHI blue staining was an independent predictor of pathological positivity (OR 3.58, 95% CI: 1.21-10.60, p = 0.02), while the 99mTc signal was not significant in the same model (p = 0.39).
CONCLUSION
MHI was comparable to 99mTc in safety and SLN detection rates but differed in sensitivity on positive SLNs.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.