DOI 10.1016/j.amjsurg.2024.116047
Examining the false-negative rate of a negative axillary node ultrasound-guided core needle biopsy in breast cancer patients undergoing upfront surgery.
Аннотация
BACKGROUND
Axillary assessment in breast cancer is key to determining an upfront surgery or neoadjuvant chemotherapy (NAC) approach. We investigated the false-negative rate (FNR) of axillary-node ultrasound-guided core-needle biopsy (US-CNBx) and the surgical management of pN + patients.
METHODS
This single-institution study from 2010 to 2020 included patients with benign findings on US-CNBx and upfront surgery. Statistical analyses were performed via t-tests and chi-squared tests.
RESULTS
95 axillae met inclusion, 23 were pN+, resulting in a US-CNBx FNR of 24.2 %. pN + patients more frequently had cT2-T3 tumors vs pN0 patients (43.5 % vs 27.8 %, p = 0.03). Of the 23 pN + patients, 9 underwent breast-conserving surgery (BCS) and 14 underwent mastectomy. In those with BCS, 7 had 1-2 positive nodes, 2 had ≥3 nodes; 3 received an ALND. In those with mastectomies, 12 had 1-2 positive nodes, 2 had ≥3 positive nodes; 6 received an ALND.
CONCLUSION
In this cohort, US-CNBx had a FNR of 24.2 %. pN + patients had a greater frequency of cT2-cT3 tumors, therefore clinicians should be cognizant of potential occult nodal disease despite negative CNBx when deciding management.