MedElevator Войти в исследования
← Поиск публикаций

DOI 10.17116/hirurgia202410149

Медицинская библиотека · Khirurgiia · 2024

[Diagnostic value of fluorescence lymphography for sentinel lymph node biopsy in breast cancer. Summary experience of several specialized centers].

Bozhok A A, Zikiryakhodzhaev A D, Kvetenadze G E, Moshurova M V, Timoshkin V O, Shomova M V, Manelov A E

Аннотация на английскомСтатьяОригинал на русском

Аннотация

OBJECTIVE

To study the diagnostic value of fluorescent lymphography for sentinel lymph node biopsy in breast cancer.

MATERIAL AND

METHODS

The cohort study, conducted at 4 specilized centers between June 2019 and March 2024, included 333 patients with cT1-4 N0-1M0 breast cancer. 50 patients received neoadjuvant systemic therapy, 14 of them had single metastases, confirmed by cytological or histological methods, which clinically completely regressed after systemic treatment. Immediately before the operation, 1 ml (5mg) of indocyanine green was injected subareolarly or subcutaneously into the tumor projection. Fluorescence imaging was performed using various devices for ICG navigation in the open surgical field - MARS, IC-Flow, Stryker SPY-PHI, IC-GOR. In 78 patients after sentinel lymph node biopsy standard axillary lymphadenectomy was performed.

RESULTS

Detection level was 99.1%. The average number of sentinel lymph nodes was 3.4. Metastatic lesions of sentinel lymph nodes were detected in 54 of 330 patients (16.4%). The average number of metastatic lymph nodes was 1.6; in 90.7% of cases metastases to 1-2 lymph nodes were registered. Intraoperative morphological examination revealed metastases only in 59% of cases. No systemic adverse events were recorded. The false-negative error rate in the group of patients who underwent axillary lymphadenectomy was 6.6%. The overall accuracy of fluorescent lymphography for sentinel lymph node biopsy in breast cancer was 94%.

CONCLUSION

The SLNB technique using fluorescence lymphography is safe and highly accurate as a stand-alone method.

Для цитирования: Bozhok A A, Zikiryakhodzhaev A D, Kvetenadze G E, Moshurova M V, Timoshkin V O, Shomova M V, Manelov A E. [Diagnostic value of fluorescence lymphography for sentinel lymph node biopsy in breast cancer. Summary experience of several specialized centers].. Khirurgiia. 2024. DOI: 10.17116/hirurgia202410149.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.