MedElevator Войти в исследования
← Поиск публикаций

DOI 10.21873/invivo.13724

Медицинская библиотека · In vivo (Athens, Greece) · 2024

Management of the Axilla After Neoadjuvant Chemotherapy: Can Axillary Needle Biopsy Replace Sentinel Node Biopsy?

Yildirim Emine, Basim Pelin, Ucar Nese, Bektas Sibel, Iscen Kutay, Karci Ebru, Ozdemir Asena Ayca

СтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND/AIM: The aim of the study was to investigate whether it is possible to evaluate the axilla after treatment without performing sentinel lymph node biopsy (SLNB) in breast cancer patients with biopsy-proven axillary lymph node metastases who received neoadjuvant chemotherapy (NAC).

PATIENTS AND

METHODS

This prospective, randomized, clinically designed study included patients with clinical T1-3 and biopsy-proven N1 breast cancer. Prior to the surgery scheduled after NAC, the patients were randomized into two groups. A biopsy sample was obtained from the clipped axillary lymph node, which was preoperatively known to be metastatic, using fine needle aspiration (FNAB) in the first group and core needle biopsy (CNB) in the second group. The predictive ability of the two biopsy methods for the SLNB results was evaluated.

RESULTS

The study included 50 female patients with breast cancer, with a mean age of 48.4±10.72 years. In both groups, metastasis was detected in nine patients, and no metastasis was seen in 14 patients. In intergroup comparisons, all patients with metastasis in the FNAB group also had metastasis according to SLNB, while 21.4% of the cases without metastasis in this group were metastatic according to SLNB. In the CNB group, metastasis was observed in all patients with metastasis according to SLNB, while no metastasis was detected in those who were reported to have no metastasis by SLNB. The accuracy, specificity, and sensitivity values for the prediction of SLNB results were all found to be 100% for CNB, whereas they were 87%, 100%, and 75%, respectively, for FNAB.

CONCLUSION

Both CNB and FNAB could potentially replace SLNB due to their high accuracy rates in evaluating the axilla after NAC. The sensitivity and accuracy of CNB were determined to be higher.

Для цитирования: Yildirim Emine, Basim Pelin, Ucar Nese, Bektas Sibel, Iscen Kutay, Karci Ebru, Ozdemir Asena Ayca. Management of the Axilla After Neoadjuvant Chemotherapy: Can Axillary Needle Biopsy Replace Sentinel Node Biopsy?. In vivo (Athens, Greece). 2024. DOI: 10.21873/invivo.13724.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.