MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/aor.15001

Медицинская библиотека · Artificial organs · 2025

Flow Mode-Dependent Regulation of von Willebrand Factor Degradation in Mechanical Circulatory Support.

Wang Haiwang, Li Chuanlong, Li Duo, Chen Yuansen, Li Wenli, Liu Yanqing, Li Yongnan, Fan Haojun, Hou Shike

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Among patients reliant on continuous-flow (CF) mechanical circulatory support devices, bleeding is primarily caused by an acquired von Willebrand factor (vWF) deficiency, precipitated by the high shear stress and diminished pulsatility inherent to these systems. However, despite its clinical significance, the relationship between these devices' flow modes and the development of vWF defects remains poorly investigated. Herein, we conducted molecular dynamic (MD) simulations and in vivo validation to investigate this relationship.

METHODS

This study involved the analysis of a novel flow sensory mechanism of the vWF molecule, elucidating the inherent relationship through an integrated approach including simulations, an in vitro flow platform, and experiments involving rats undergoing venoarterial extracorporeal membrane oxygenation (V-A ECMO).

RESULTS

MD simulations demonstrated that the vWF-A dimer underwent significant retraction under pulsatile-flow (PF) conditions, indicating an autoinhibitory effect on enzymatic cleavage. Conversely, under CF conditions, we observed a pronounced reduction in circulating vWF levels and a decrease in endothelial cell vWF secretion compared with both the PF and sham groups of rats undergoing V-A ECMO.

CONCLUSION

These findings underscore the critical importance of pulsatility in the design of next-generation blood pumps and highlight the potential of our novel rat model in future investigations of the physiological and molecular responses to different blood flow patterns during V-A ECMO.

Для цитирования: Wang Haiwang, Li Chuanlong, Li Duo, Chen Yuansen, Li Wenli, Liu Yanqing, Li Yongnan, Fan Haojun, Hou Shike. Flow Mode-Dependent Regulation of von Willebrand Factor Degradation in Mechanical Circulatory Support.. Artificial organs. 2025. DOI: 10.1111/aor.15001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.