MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.landig.2025.02.003

Медицинская библиотека · The Lancet. Digital health · 2025

Snapshot artificial intelligence-determination of ejection fraction from a single frame still image: a multi-institutional, retrospective model development and validation study.

Malins Jeffrey G, Anisuzzaman D M, Jackson John I, Lee Eunjung, Naser Jwan A, Rostami Behrouz, Bird Jared G, Spiegelstein Dan, Amar Talia, Oh Jae K, Pellikka Patricia A, Thaden Jeremy J, Lopez-Jimenez Francisco, Pislaru Sorin V, Friedman Paul A, Kane Garvan C, Attia Zachi I

СтатьяВалидационное исследованиеМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Artificial intelligence (AI) is poised to transform point-of-care practice by providing rapid snapshots of cardiac functioning. Although previous AI models have been developed to estimate left ventricular ejection fraction (LVEF), they have typically used video clips as input, which can be computationally intensive. In the current study, we aimed to develop an LVEF estimation model that takes in static frames as input.

METHODS

Using retrospective transthoracic echocardiography (TTE) data from Mayo Clinic Rochester and Mayo Clinic Health System sites (training: n=19 627; interval validation: n=862), we developed a two-dimensional convolutional neural network model that provides an LVEF estimate associated with an input frame from an echocardiogram video. We then evaluated model performance for Mayo Clinic TTE data (Rochester, n=1890; Arizona, n=1695; Florida, n=1862), the EchoNet-Dynamic TTE dataset (n=10 015), a prospective cohort of patients from whom TTE and handheld cardiac ultrasound (HCU) were simultaneously collected (n=625), and a prospective cohort of patients from whom HCU clips were collected by expert sonographers and novice users (n=100, distributed across three external sites).

FINDINGS: We observed consistently strong model performance when estimates from single frames were averaged across multiple video clips, even when only one frame was taken per video (for classifying LVEF ≤40% vs LVEF>40%, area under the receiver operating characteristic curve [AUC]>0·90 for all datasets except for HCU clips collected by novice users, for which AUC>0·85). We also observed that LVEF estimates differed slightly depending on the phase of the cardiac cycle when images were captured.

INTERPRETATION: When aiming to rapidly deploy such models, single frames from multiple videos might be sufficient for LVEF classification. Furthermore, the observed sensitivity to the cardiac cycle offers some insights on model performance from an explainability perspective.

FUNDING: Internal institutional funds provided by the Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA.

Для цитирования: Malins Jeffrey G, Anisuzzaman D M, Jackson John I, Lee Eunjung, Naser Jwan A, Rostami Behrouz, Bird Jared G, Spiegelstein Dan, Amar Talia, Oh Jae K, Pellikka Patricia A, Thaden Jeremy J, Lopez-Jimenez Francisco, Pislaru Sorin V, Friedman Paul A, Kane Garvan C, Attia Zachi I. Snapshot artificial intelligence-determination of ejection fraction from a single frame still image: a multi-institutional, retrospective model development and validation study.. The Lancet. Digital health. 2025. DOI: 10.1016/j.landig.2025.02.003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.