MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/ehjimp/qyae092

Медицинская библиотека · European heart journal. Imaging methods and practice · 2024

Deep learning improves test-retest reproducibility of regional strain in echocardiography.

Nyberg John, Østvik Andreas, Salte Ivar M, Olaisen Sindre, Karlsen Sigve, Dahlslett Thomas, Smistad Erik, Eriksen-Volnes Torfinn, Brunvand Harald, Edvardsen Thor, Haugaa Kristina H, Lovstakken Lasse, Dalen Havard, Grenne Bjørnar

СтатьяПеревод пока не подготовлен

Аннотация

AIMS: The clinical utility of regional strain measurements in echocardiography is challenged by suboptimal reproducibility. In this study, we aimed to evaluate the test-retest reproducibility of regional longitudinal strain (RLS) per coronary artery perfusion territory (RLSTerritory) and basal-to-apical level of the left ventricle (RLSLevel), measured by a novel fully automated deep learning (DL) method based on point tracking.

METHODS AND

RESULTS

We measured strain in a dual-centre test-retest data set that included 40 controls and 40 patients with suspected non-ST elevation acute coronary syndrome. Two consecutive echocardiograms per subject were recorded by different operators. The reproducibility of RLSTerritory and RLSLevel measured by the DL method and by three experienced observers using semi-automatic software (2D Strain, EchoPAC, GE HealthCare) was evaluated as minimal detectable change (MDC). The DL method had MDC for RLSTerritory and RLSLevel ranging from 3.6 to 4.3%, corresponding to a 33-35% improved reproducibility compared with the inter- and intraobserver scenarios (MDC 5.5-6.4% and 4.9-5.4%). Furthermore, the DL method had a lower variance of test-retest differences for both RLSTerritory and RLSLevel compared with inter- and intraobserver scenarios (all P < 0.001). Bland-Altman analyses demonstrated superior reproducibility by the DL method for the whole range of strain values compared with the best observer scenarios. The feasibility of the DL method was 93% and measurement time was only 1 s per echocardiogram.

CONCLUSION

The novel DL method provided fully automated measurements of RLS, with improved test-retest reproducibility compared with semi-automatic measurements by experienced observers. RLS measured by the DL method has the potential to advance patient care through a more detailed, more efficient, and less user-dependent clinical assessment of myocardial function.

Для цитирования: Nyberg John, Østvik Andreas, Salte Ivar M, Olaisen Sindre, Karlsen Sigve, Dahlslett Thomas, Smistad Erik, Eriksen-Volnes Torfinn, Brunvand Harald, Edvardsen Thor, Haugaa Kristina H, Lovstakken Lasse, Dalen Havard, Grenne Bjørnar. Deep learning improves test-retest reproducibility of regional strain in echocardiography.. European heart journal. Imaging methods and practice. 2024. DOI: 10.1093/ehjimp/qyae092.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.