MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/eurheartj/ehad431

Медицинская библиотека · European heart journal · 2024

Artificial intelligence in detecting left atrial appendage thrombus by transthoracic echocardiography and clinical features: the Left Atrial Thrombus on Transoesophageal Echocardiography (LATTEE) registry.

Pieszko Konrad, Hiczkiewicz Jarosław, Łojewska Katarzyna, Uziębło-Życzkowska Beata, Krzesiński Paweł, Gawałko Monika, Budnik Monika, Starzyk Katarzyna, Wożakowska-Kapłon Beata, Daniłowicz-Szymanowicz Ludmiła, Kaufmann Damian, Wójcik Maciej, Błaszczyk Robert, Mizia-Stec Katarzyna, Wybraniec Maciej, Kosmalska Katarzyna, Fijałkowski Marcin, Szymańska Anna, Dłużniewski Mirosław, Kucio Michał, Haberka Maciej, Kupczyńska Karolina, Michalski Błażej, Tomaszuk-Kazberuk Anna, Wilk-Śledziewska Katarzyna, Wachnicka-Truty Renata, Koziński Marek, Kwieciński Jacek, Wolny Rafał, Kowalik Ewa, Kolasa Iga, Jurek Agnieszka, Budzianowski Jan, Burchardt Paweł, Kapłon-Cieślicka Agnieszka, Slomka Piotr J

СтатьяПеревод пока не подготовлен

Аннотация

AIMS: Transoesophageal echocardiography (TOE) is often performed before catheter ablation or cardioversion to rule out the presence of left atrial appendage thrombus (LAT) in patients on chronic oral anticoagulation (OAC), despite associated discomfort. A machine learning model [LAT-artificial intelligence (AI)] was developed to predict the presence of LAT based on clinical and transthoracic echocardiography (TTE) features.

METHODS AND

RESULTS

Data from a 13-site prospective registry of patients who underwent TOE before cardioversion or catheter ablation were used. LAT-AI was trained to predict LAT using data from 12 sites (n = 2827) and tested externally in patients on chronic OAC from two sites (n = 1284). Areas under the receiver operating characteristic curve (AUC) of LAT-AI were compared with that of left ventricular ejection fraction (LVEF) and CHA2DS2-VASc score. A decision threshold allowing for a 99% negative predictive value was defined in the development cohort. A protocol where TOE in patients on chronic OAC is performed depending on the LAT-AI score was validated in the external cohort. In the external testing cohort, LAT was found in 5.5% of patients. LAT-AI achieved an AUC of 0.85 [95% confidence interval (CI): 0.82-0.89], outperforming LVEF (0.81, 95% CI 0.76-0.86, P < .0001) and CHA2DS2-VASc score (0.69, 95% CI: 0.63-0.7, P < .0001) in the entire external cohort. Based on the proposed protocol, 40% of patients on chronic OAC from the external cohort would safely avoid TOE.

CONCLUSION

LAT-AI allows accurate prediction of LAT. A LAT-AI-based protocol could be used to guide the decision to perform TOE despite chronic OAC.

Для цитирования: Pieszko Konrad, Hiczkiewicz Jarosław, Łojewska Katarzyna, Uziębło-Życzkowska Beata, Krzesiński Paweł, Gawałko Monika, Budnik Monika, Starzyk Katarzyna, Wożakowska-Kapłon Beata, Daniłowicz-Szymanowicz Ludmiła, Kaufmann Damian, Wójcik Maciej, Błaszczyk Robert, Mizia-Stec Katarzyna, Wybraniec Maciej, Kosmalska Katarzyna, Fijałkowski Marcin, Szymańska Anna, Dłużniewski Mirosław, Kucio Michał, Haberka Maciej, Kupczyńska Karolina, Michalski Błażej, Tomaszuk-Kazberuk Anna, Wilk-Śledziewska Katarzyna, Wachnicka-Truty Renata, Koziński Marek, Kwieciński Jacek, Wolny Rafał, Kowalik Ewa, Kolasa Iga, Jurek Agnieszka, Budzianowski Jan, Burchardt Paweł, Kapłon-Cieślicka Agnieszka, Slomka Piotr J. Artificial intelligence in detecting left atrial appendage thrombus by transthoracic echocardiography and clinical features: the Left Atrial Thrombus on Transoesophageal Echocardiography (LATTEE) registry.. European heart journal. 2024. DOI: 10.1093/eurheartj/ehad431.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.