INTRODUCTION

The incidence of new permanent pacemaker implantation (PPI) after rapid deployment aortic valve replacement (RDAVR) remains debated. Expertise in this field has significantly increased over the last decade. This study aimed to investigate the need for PPI following implantation of a rapid deployment (RD) valve.

METHODS

Analysis of n=372 patients who underwent Edwards INTUITY (Edwards Lifesciences, Irvine, CA, USA) (n=251) and Perceval (Sorin/LivaNova Group, Saluggia, Italy) (n=121) valve replacement at the current institution between May 2012 and August 2018 was performed. Coronary artery bypass graft procedures were additionally performed in patients with coronary artery disease. Baseline, preoperative and postoperative outcomes were examined regarding correctness and completeness of the procedure. Statistical analysis was performed using SPSS Version 23.0.0 (IBM Corp, Armonk, NY, USA).

RESULTS

A total of 372 patients (aged 75±6.3 yrs) with a high grade of aortic valve stenosis underwent either Edwards INTUITY (67%) or Perceval (33%) valve replacement. Seventy-six (76) patients (20%) presented with preoperative conduction disorders. Sixty (60) patients (16%) underwent PPI, which in most cases was performed during the first month after the initial operation. Follow-up was performed up to 9 years, presenting a persistent pacemaker dependency rate of 50% among all patients who underwent PPI. Twenty (20) (40%) PPI recipients showed no dependency on pacemaker, while 10 (10%) required temporary pacemaker support. Mean length of ICU stay was 4±5.1 days and in-hospital stay was 8.2±7.6 days.

CONCLUSIONS

The incidence of PPI after RD valve implantation still remains high compared with conventional aortic valve replacement. However, this study shows that this phenomenon appears to be transient in a significant proportion of the patients undergoing RD valve replacement. These findings might contribute to the scientific discussion and should be taken into consideration for the indication of RD valve replacement.

Для цитирования: Krasivskyi Ihor, Djordjevic Ilija, Ivanov Borko, Gerfer Stephen, Suhr Laura, Avgeridou Soi, Sabashnikov Anton, Kuhn Elmar, Rahmanian Parwis, Mader Navid, Eghbalzadeh Kaveh, Wahlers Thorsten. High Incidence of Transient Permanent Pacemaker Rate After Rapid Deployment Valve Replacement: Insights of a 9-Year Single-Centre Experience.. Heart, lung & circulation. 2022. DOI: 10.1016/j.hlc.2022.08.003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.