Refractive Nightmares Revisited: Calcification of a Multifocal Intraocular Lens.

Moschos Marilita M, Laios Konstantinos, Lavaris Anastasios, Damaskos Christos, Garmpis Nikolaos, Thabit Ahmed, Lake Damian, Hamada Samer, Garmpi Anna, Gatzioufas Zisis

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND/AIM: Cataract is the leading cause of reversible blindness and visual impairment worldwide. Although cataract surgery using phacoemulsification and intraocular lens (IOL) implantation is one of the commonest surgical procedures, IOL opacification remains a potential complication that can affect the visual outcome of the operation.

CASE REPORT: A 50-year-old female patient presented to our clinic complaining of glare and blurry vision in her right eye over the previous 6 weeks. She had undergone bilateral refractive lens exchange elsewhere 9 months earlier. Her unaided distance visual acuity was 8/10 in the right eye and 10/10 in the left. On slit-lamp examination, we observed the presence of in-the-bag, multifocal, hydrophobic acrylic IOLs bilaterally. Specifically, calcified deposits within the substance of the IOL were observed.

CONCLUSION

To our knowledge, this is the first case of spontaneous calcification of a hydrophobic multifocal IOL and all cataract/refractive surgeons should be aware of this rare complication.

Для цитирования: Moschos Marilita M, Laios Konstantinos, Lavaris Anastasios, Damaskos Christos, Garmpis Nikolaos, Thabit Ahmed, Lake Damian, Hamada Samer, Garmpi Anna, Gatzioufas Zisis. Refractive Nightmares Revisited: Calcification of a Multifocal Intraocular Lens.. In vivo (Athens, Greece). 2018. DOI: 10.21873/invivo.11375.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.