International journal of surgical oncology · 2013
Sentinel lymph node detection using laser-assisted indocyanine green dye lymphangiography in patients with melanoma.
Оценочное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Jain Vikalp, Phillips Brett T, Conkling Nicole, Pameijer Colette
Аннотация
INTRODUCTION: Sentinel lymph node (SLN) biopsy is a vital component of staging and management of multiple cancers. The current gold standard utilizes technetium 99 (tech99) and a blue dye to detect regional nodes. While the success rate is typically over 90%, these two methods can be inconclusive or inconvenient for both patient and surgeon. We evaluated a new technique using laser-assisted ICG dye lymphangiography to identify SLN.
METHODS: In this retrospective analysis, we identified patients with melanoma who were candidates for SLN biopsy. In addition to tech99 and methylene blue, patients received a dermal injection of indocyanine green (ICG). The infrared signal was detected with the SPY machine (Novadaq), and nodes positive by any method were excised.
RESULTS: A total of 15 patients were evaluated, with 40 SLNs removed. Four patients were found to have nodal metastases on final pathology. 100% of these 4 nodes were identified by ICG, while only 75% (3/4) were positive for tech99 and/or methylene blue. Furthermore, none of the nodes missed by ICG (4/40) had malignant cells.
CONCLUSION: ICG dye lymphangiography is a reasonable alternative for locating SLNs in patients with melanoma. Prospective studies are needed to better ascertain the full functionality of this technique.
METHODS: In this retrospective analysis, we identified patients with melanoma who were candidates for SLN biopsy. In addition to tech99 and methylene blue, patients received a dermal injection of indocyanine green (ICG). The infrared signal was detected with the SPY machine (Novadaq), and nodes positive by any method were excised.
RESULTS: A total of 15 patients were evaluated, with 40 SLNs removed. Four patients were found to have nodal metastases on final pathology. 100% of these 4 nodes were identified by ICG, while only 75% (3/4) were positive for tech99 and/or methylene blue. Furthermore, none of the nodes missed by ICG (4/40) had malignant cells.
CONCLUSION: ICG dye lymphangiography is a reasonable alternative for locating SLNs in patients with melanoma. Prospective studies are needed to better ascertain the full functionality of this technique.