Feasibility, safety and efficacy of transcutaneous vagus nerve stimulation in chronic tinnitus: an open pilot study.

Kreuzer Peter M, Landgrebe Michael, Resch Markus, Husser Oliver, Schecklmann Martin, Geisreiter Florian, Poeppl Timm B, Prasser Sarah J, Hajak Goeran, Rupprecht Rainer, Langguth Berthold

Клиническое исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

Vagus nerve stimulation represents an established treatment strategy for epilepsy and affective disorders. Recently, positive effects were also shown in animals and humans with tinnitus. Here we report the results of an open pilot study exploring feasibility, safety and efficacy of tVNS in the treatment of chronic tinnitus.

STUDY

DESIGN

Fifty patients with chronic tinnitus underwent tVNS in an open single-armed pilot study which was conducted in two phases applying two different stimulating devices (Cerbomed CM02 and NEMOS). Clinical assessment was based on Tinnitus Questionnaire (TQ), Tinnitus Handicap Inventory (THI), Beck Depression Inventory (BDI), WHO Quality of Life, and various numeric rating scales. Primary outcome was defined as change in TQ (baseline vs. final visit in week 24). The study has been registered with clinicaltrials.gov (NCT01176734).

RESULTS

Primary analysis indicated mean TQ reductions of 3.7 points (phase 1) and 2.8 points (phase 2) significant for the first study phase. Secondary analyses indicated a significant BDI reduction for phase 1 (uncorrected for multiple testing), but no further systematic or significant effects. Adverse events included twitching and pressure at electrode placement site. The occurrence of one hospitalization because of palpations and the development of a left bundle branch block were considered as unrelated to the intervention. Cognitive testing revealed no significant changes.

CONCLUSION

Our data demonstrate the feasibility of tVNS over a period of 6 months. There was no clinically relevant improvement of tinnitus complaints. Our data suggest tVNS to be considered safe in patients without a history of cardiac disease.

Для цитирования: Kreuzer Peter M, Landgrebe Michael, Resch Markus, Husser Oliver, Schecklmann Martin, Geisreiter Florian, Poeppl Timm B, Prasser Sarah J, Hajak Goeran, Rupprecht Rainer, Langguth Berthold. Feasibility, safety and efficacy of transcutaneous vagus nerve stimulation in chronic tinnitus: an open pilot study.. Brain stimulation. 2014. DOI: 10.1016/j.brs.2014.05.003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.