Tersalvi Gregorio, Carey Patricia, Garmany Armin, Scott Christopher G, Davies Daniel R, Jouni Hayan, Rodriguez-Porcel Martin G, Askew J Wells, Bois John P, Young Kathleen A, Anavekar Nandan S, Chang Ian C, Pellikka Patricia A, Grogan Martha, Dispenzieri Angela, Homb Andrew C, Johnson Geoffrey B, Chareonthaitawee Panithaya, AbouEzzeddine Omar F

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Cardiac amyloid radionuclide imaging (CARI) with 99mTc-pyrophosphate (PYP) enables the noninvasive diagnosis of transthyretin amyloid cardiomyopathy (ATTR-CM). Recent PYP shortages have necessitated substitution with 99mTc-hydroxymethylene diphosphonate (HMDP), yet direct comparative data are limited. We aimed to compare scan interpretation, ATTR-CM prevalence, and myocardial-to-blood pool discrimination between PYP and HMDP in real-world clinical practice.

METHODS

We retrospectively analyzed 992 consecutive patients who underwent SPECT/CT for suspected ATTR-CM at a single referral center between October 2022 and January 2025. PYP was used except during two shortage periods (December 2023 to February 2024 and October 2024 to January 2025), when HMDP was substituted. Scan interpretation and final ATTR-CM diagnoses were recorded. The myocardial-to-blood-pool radiotracer uptake ratio (3D Score) was measured as a surrogate for contrast resolution.

RESULTS

Of 992 unique patients (median age 76, 27% female), 816 received PYP and 176 (18%) received HMDP. Baseline clinical, echocardiographic, and biomarker characteristics were similar between groups. Rates of positive scans (PYP: 26%, HMDP: 25%; P = 0.95) and final ATTR-CM diagnoses (28% vs 26%; P = 0.59) were comparable. Among patients with positive scans (n = 256), HMDP yielded significantly higher 3D Scores (2.0 [1.7-2.5] vs 1.4 [1.2-1.7], P < 0.001), suggesting enhanced myocardial-to-blood pool contrast resolution.

CONCLUSIONS

In a large cohort with similar clinical profiles, HMDP provided equivalent diagnostic yield and superior myocardial-to-blood-pool discrimination compared to PYP. These findings support HMDP as a good alternative during PYP shortages, with potential advantages in contrast resolution.

Для цитирования: Tersalvi Gregorio, Carey Patricia, Garmany Armin, Scott Christopher G, Davies Daniel R, Jouni Hayan, Rodriguez-Porcel Martin G, Askew J Wells, Bois John P, Young Kathleen A, Anavekar Nandan S, Chang Ian C, Pellikka Patricia A, Grogan Martha, Dispenzieri Angela, Homb Andrew C, Johnson Geoffrey B, Chareonthaitawee Panithaya, AbouEzzeddine Omar F. Comparative performance of 99mTc-pyrophosphate vs. 99mTc-hydroxymethylene diphosphonate for cardiac amyloid radionuclide imaging.. Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology. 2025. DOI: 10.1016/j.nuclcard.2025.102587.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.