MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/112067211002000110

Медицинская библиотека · European journal of ophthalmology · 2010

Comparison of internal anterior chamber diameter measured with ultrabiomicroscopy with white-to-white distance measured using digital photography in aphakic eyes.

Wilczynski Michal, Bartela Joanna, Synder Aleksandra, Omulecki Wojciech

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: Measuring the anterior chamber diameter (AC) is important both for diagnostics and before ocular surgery. In clinical practice, horizontal AC diameter is usually estimated on the basis of measurements of corneal diameter (so-called white-to-white [WTW] distance). The usual method for selecting an appropriate size for an AC lens is to add 1 mm to WTW measurement. The purpose of this study was to compare AC diameter measured using ultrasound biomicroscopy (UBM) with WTW distance measured using digital photography in aphakic eyes.

METHODS

The data were gathered prospectively from a nonrandomized consecutive series of aphakic patients. The examined group consisted of 23 eyes of 23 adult patients, mean age 71.17 years. WTW diameter was measured in the 3 o'clock and 9 o'clock meridian on a digital photograph. Internal horizontal AC diameter measurements were performed in the 3 o'clock and 9 o'clock meridian with the Sonomed Ultrabiomicroscopy device with a 50-MHz probe.

RESULTS

Mean horizontal WTW diameter measured using digital photographs was 11.65+/-0.38 mm and mean horizontal internal AC diameter measured using UBM was 13.53+/-0.83 mm. A significant difference in mean WTW diameter measured using digital photography and UBM was found (Mann-Whitney U test, p<0.05). There was a significant correlation between these values (Spearman=0.70, p<0.001).

CONCLUSIONS

In order to obtain good and precise measurements of internal AC diameter, a method of direct visualization of the intraocular structures should be used. Despite the limits of a small case series, our results support the use of UBM technique for preoperative evaluation of the internal AC diameter and AC intraocular lens sizing in aphakic eyes.

Для цитирования: Wilczynski Michal, Bartela Joanna, Synder Aleksandra, Omulecki Wojciech. Comparison of internal anterior chamber diameter measured with ultrabiomicroscopy with white-to-white distance measured using digital photography in aphakic eyes.. European journal of ophthalmology. 2010. DOI: 10.1177/112067211002000110.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.