Visual field defects and changes in macular retinal ganglion cell complex thickness in eyes with intrachoroidal cavitation are similar to those in early glaucoma.

Okuma Shinichi, Mizoue Shiro, Ohashi Yuichi

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND/AIMS: To examine the characteristics of visual field defects and optical coherence tomography (OCT) findings in eyes with intrachoroidal cavitation (ICC) and investigate the similarities between these results and glaucomatous changes.

METHODS

We retrospectively analyzed patients diagnosed with ICC based on peripapillary radial cross-sectional scans performed with OCT. Visual field was measured with the Humphrey automated visual field analyzer SITA standard central 24-2 program, and macular ganglion cell complex (GCC) thickness was measured in 9×9 mm areas on OCT. The positive rates for the Anderson criteria, site of visual field defect, and mean GCC thickness in each quadrant were compared; the association between these results and ICC location was assessed.

RESULTS

Fifteen eyes from eleven patients (five males and six females; mean age, 54.6±10.7 years) were selected for investigation. ICC was detected in the inferior temporal side of the optic disc in all studied eyes. The positive rate for the Anderson criteria was 73.3% (11/15 eyes). Visual field defects were most commonly observed in the cluster that corresponded to the superior Bjerrum area (53.3%; 8/15 eyes). GCC thickness was significantly lower in the inferior side, where the ICC was located, than the superior side, where the ICC was absent (P=0.0001). GCC thinning that correlated with ICC was observed in 66.7% (10/15 eyes) of the ICC eyes.

CONCLUSION

Visual field and GCC findings on OCT in ICC eyes are extremely similar to those observed in superior visual field defect-type early glaucoma, indicating a possible difficulty in distinguishing the two conditions.

Для цитирования: Okuma Shinichi, Mizoue Shiro, Ohashi Yuichi. Visual field defects and changes in macular retinal ganglion cell complex thickness in eyes with intrachoroidal cavitation are similar to those in early glaucoma.. Clinical ophthalmology (Auckland, N.Z.). 2016. DOI: 10.2147/opth.s102130.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.