MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/arm91010001

Медицинская библиотека · Advances in respiratory medicine · 2023

Diagnostic Accuracy of Slow-Capillary Endobronchial Ultrasound Needle Aspiration in Determining PD-L1 Expression in Non-Small Cell Lung Cancer.

Zuccatosta Lina, Mei Federico, Sediari Michele, Di Marco Berardino Alessandro, Bonifazi Martina, Barbisan Francesca, Goteri Gaia, Gasparini Stefano, Gonnelli Francesca

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

The role of EBUS-TBNA in the diagnosis and staging of lung cancer is well established. EBUS-TBNA can be performed using different aspiration techniques. The most common aspiration technique is known as "suction". One alternative to the suction technique is the slow-pull capillary aspiration. To the best of our knowledge, no studies have assessed the diagnostic yield of slow-pull capillary EBUS-TBNA in PD-L1 amplification assessment in NSCLC. Herein, we conducted a single-centre retrospective study to establish the diagnostic yield of slow-pull capillary EBUS-TBNA in terms of PD-L1 in patients with NSCLC and hilar/mediastinal lymphadenopathies subsequent to NSCLC.

MATERIALS AND

METHODS

Patients with hilar and/or mediastinal lymph node (LN) NSCLC metastasis, diagnosed by EBUS-TBNA between January 2021 and April 2022 at Pulmonology Unit of "Ospedali Riuniti di Ancona" (Ancona, Italy) were enrolled. We evaluated patient characteristics, including demographic information, CT scan/ FDG-PET features and final histological diagnoses, including PD-L1 assessment.

RESULTS

A total of 174 patients underwent EBUS-TBNA for diagnosis of hilar/mediastinal lymphadenopathies between January 2021 and April 2022 in the Interventional Pulmonology Unit of the "Ospedali Riuniti di Ancona". Slow-pull capillary aspiration was adopted in 60 patients (34.5%), and in 30/60 patients (50.0%) NSCLC was diagnosed. EBUS-TBNA with slow-pull capillary aspiration provided adequate sampling for molecular biology and PD-L1 testing in 96.7% of patients (29/30); in 15/29 (51.7%) samples with more than 1000 viable cells/HPF were identified, whereas in 14/29 (48.3%) samples contained 101-1000 viable cells/HPF.

CONCLUSION

These retrospective study shows that slow-pull capillary aspiration carries an excellent diagnostic accuracy, almost equal to that one reported in literature, supporting its use in EBUS-TBNA for PD-L1 testing in NSCLC.

Для цитирования: Zuccatosta Lina, Mei Federico, Sediari Michele, Di Marco Berardino Alessandro, Bonifazi Martina, Barbisan Francesca, Goteri Gaia, Gasparini Stefano, Gonnelli Francesca. Diagnostic Accuracy of Slow-Capillary Endobronchial Ultrasound Needle Aspiration in Determining PD-L1 Expression in Non-Small Cell Lung Cancer.. Advances in respiratory medicine. 2023. DOI: 10.3390/arm91010001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.