MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/00003246-199502000-00013

Медицинская библиотека · Critical care medicine · 1995

Pressure-controlled, inverse ratio ventilation that avoids air trapping in the adult respiratory distress syndrome.

Armstrong B W, MacIntyre N R

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To investigate physiologic and outcome data in patients switched from volume-cycled conventional ratio ventilation to pressure-controlled inverse ratio ventilation that did not produce air trapping and intrinsic positive end-expiratory pressure (PEEP).

SETTING

Medical intensive care unit.

DESIGN

Retrospective analysis of crossover data and outcome.

PATIENTS: Fourteen patients with the adult respiratory distress syndrome who were receiving mechanical ventilation with volume-cycled, conventional ratio ventilation followed by pressure-controlled, inverse ratio ventilation.

INTERVENTIONS: Our approach to pressure-controlled, inverse ratio ventilation was to use tidal volumes and applied PEEP values comparable to those volumes and values used on volume-cycled, conventional ratio ventilation, use inspiratory times to increase mean airway pressure instead of additional applied PEEP, and avoid air trapping (intrinsic PEEP).

MEASUREMENTS AND MAIN

RESULTS

With this approach, there was a reduction in peak airway pressure from 53 +/- 8.5 (SD) to 40 +/- 5.9 cm H2O (p < .01), and an increase in mean airway pressure from 20 +/- 3.9 to 30 +/- 5.2 cm H2O (p < .01). Tidal volume, mean inflation pressure, and compliance did not change. Oxygenation (PaO2) improved from 57 +/- 11.3 torr (7.6 +/- 1.5 kPa) to 94 +/- 40.2 torr (12.5 +/- 5.4 kPa) (p = .01) but the oxygenation index (mean airway pressure x FIO2 x 100/PaO2) did not change significantly (25.9 +/- 10.3 to 27.2 +/- 12.2). There was no significant change in PaCO2 or pH even though delivered minute ventilation decreased from 17.4 +/- 4.3 to 14.8 +/- 5.8 L/min (p = .02). Cardiac index slightly decreased, but hemodynamic values were otherwise stable. Only three of the 14 study patients survived.

CONCLUSIONS

These data demonstrate that oxygenation is primarily a function of mean airway pressure, and that longer inspiratory times can be used as an alternative to applied PEEP to increase this oxygenation. If no air trapping develops, lung inflation pressures and delivered volumes remain constant with this approach. Because the technique was used only in patients refractory to conventional techniques, the poor outcome is not surprising.

Для цитирования: Armstrong B W, MacIntyre N R. Pressure-controlled, inverse ratio ventilation that avoids air trapping in the adult respiratory distress syndrome.. Critical care medicine. 1995. DOI: 10.1097/00003246-199502000-00013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.