Iwasaki Eisuke, Minami Kazuhiro, Itoi Takao, Yamamoto Kenjiro, Tsuji Shujiro, Sofuni Atsushi, Tsuchiya Takayoshi, Tanaka Reina, Tonozuka Ryosuke, Machida Yujiro, Takimoto Yoichi, Tamagawa Hiroki, Katayama Tadashi, Kawasaki Shintaro, Seino Takashi, Horibe Masayasu, Fukuhara Seiichiro, Kitago Minoru, Ogata Haruhiko, Kanai Takanori

Сравнительное исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVE

Endoscopic papillectomy is increasingly being used for ampullary adenoma treatment. However, it remains challenging despite increased safety with treatment advances. The ideal power output and electrosurgical current mode for mucosal resection are not established. We aimed to identify the ideal electrical pulse for use during resection.

METHODS

This pilot randomized, single-blind, prospective, multicenter trial, recruited patients with ampullary adenomas and conventional anatomy who were scheduled to undergo endoscopic papillectomy. Endoscopic treatment was performed using a standardized algorithm and patients were randomized for endoscopic papillectomy with Endocut or Autocut. The primary outcome was the incidence of delayed bleeding. Incidence of procedure-related pancreatitis, successful complete resection, pathological findings, and other adverse events were secondary endpoints.

RESULTS

Sixty patients were enrolled over a 2-year period. The incidences of delayed bleeding (13.3% vs. 16.7%, P = 1.00) and pancreatitis (27% vs. 30%, P = 0.77) were similar between both groups. The rate of crush artifacts was higher in the Endocut than in the Autocut group (27% vs. 3.3%, P = 0.03). Immediate bleeding when resecting tumors greater than 14 mm in diameter was more common in the Autocut than in the Endocut group (88% vs. 46%, P = 0.04).

CONCLUSIONS

The Autocut and Endocut modes have similar efficacy and safety for endoscopic papillectomy. The Endocut mode may prevent immediate bleeding in cases with large tumor sizes, although it causes more frequent crush artifacts.

REGISTRY AND THE REGISTRATION NUMBER: The Japanese UMIN Clinical Trials Registry (UMIN-CTR: 000021382).

Для цитирования: Iwasaki Eisuke, Minami Kazuhiro, Itoi Takao, Yamamoto Kenjiro, Tsuji Shujiro, Sofuni Atsushi, Tsuchiya Takayoshi, Tanaka Reina, Tonozuka Ryosuke, Machida Yujiro, Takimoto Yoichi, Tamagawa Hiroki, Katayama Tadashi, Kawasaki Shintaro, Seino Takashi, Horibe Masayasu, Fukuhara Seiichiro, Kitago Minoru, Ogata Haruhiko, Kanai Takanori. Impact of electrical pulse cut mode during endoscopic papillectomy: Pilot randomized clinical trial.. Digestive endoscopy : official journal of the Japan Gastroenterological Endoscopy Society. 2019. DOI: 10.1111/den.13468.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.