Hypoplastic arteries of the cerebral arterial ring in the blind spot of computed tomography angiography.
Аннотация
BACKGROUND
Some variations of the cerebral arterial circle (CAC) are associated with an increased risk for the development of various pathological conditions. This paper aimed to determine the prevalence of hypoplastic arteries of CAC and to emphasize the limited possibility of their visualization by computed tomography angiography (CTA).
MATERIALS AND
METHODS
The research was performed on 400 adult cadavers by macro- and microdissection of the cerebral arteries. Each case was photographed and the diameter of the arteries was measured digitally, by analysing photographs of the bases of the brain in the ImageJ program.
RESULTS
The largest prevalence of artery diameter < 1 mm (< 0.6 mm) in CAC had the posterior communicating artery (PCoA). PCoA on the left side was hypoplastic in 44.9% (11.4%) of cases, while the same artery on the right side was hypoplastic in 44.3% (6.6%) of cases. The posterior cerebral artery was hypoplastic on the left side in 3% (0.6%) and on the right side in 4.2% (0.6%) of cases. The anterior cerebral artery had a hypoplastic calibre only on the right side in 2.4% (0.6%) of the cases, while the internal carotid arteries did not have a diameter < 1 mm in any case. The anterior communicating artery showed the greatest variability in morphology. Studies on CTA describe the occurrence of aplasia in a statistically significantly higher percentage, and the occurrence of hypoplastic arteries in a statistically significantly lower percentage compared to studies on cadavers.
CONCLUSIONS
Due to significant differences between cadaveric and radiological studies, it is necessary to analyse their results regarding arterial hypoplasia and aplasia separately. A diameter of less than 1 mm has been suggested as a criterion for arterial hypoplasia.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.