MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/02841851231193258

Медицинская библиотека · Acta radiologica (Stockholm, Sweden : 1987) · 2023

Reduced radiation dose and volume of contrast medium in heart rate-based, one-stop computed tomography angiography of coronary, carotid and cerebrovascular arteries.

Yu Hairong, Song Hao, Sun Xiaonan, Song Tiangang, Xie Anming, Xu Jianghua, Qin Ruiying, Jing Lihua, Zuo Taiyang, Zhao Jie, Luan Xiaomei, Wang Zengkun, Chai Huijing, Zhao Yuanzhen, Song Peiji

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Computed tomography angiography (CTA) is a reliable, non-invasive screening method for diagnosing panvascular disease. By using low contrast agent volume, CTA imaging enables one-stop multi-organ scanning, thereby minimizing the potential risk of contrast-induced nephropathy in patients with impaired renal function.

PURPOSE: To evaluate the feasibility of one-stop CTA following a heart rate (HR)-based protocol using a low volume of contrast medium (CM) for examination of the coronary, carotid and cerebrovascular arteries.

MATERIAL AND

METHODS

Sixty patients undergoing coronary carotid, and cerebrovascular CTA after a single injection of CM were recruited and randomly divided into two groups. Group A (n = 30) underwent CTA following a traditional protocol. The timing of the scans in Group B (n = 30) was determined according to the patient's HR.

RESULTS

The CT values for the thoracic aorta (432.2 ± 104.28 HU), anterior cerebral artery (303.96 ± 99.29 HU), and right coronary artery (366.70 ± 85.10 HU) in Group A did not differ significantly from those in Group B (445.80 ± 106.13, 293.73 ± 75.25 and 344.13 ± 111.04 HU, respectively). The qualities of most of the scanned images for both groups were scored as 3 or 4 (on a five-point scale). The radiation dose and the volume of CM were significantly higher in Group A (303.05 ± 110.95 mGy) (100 mL) than in Group B (239.46 ± 101.12 mGy) (50 mL).

CONCLUSION

The radiation dose and volume of CM were significantly reduced in CTA following the HR-based protocol. The personalized administration of CM also simplified the scanning process.

Для цитирования: Yu Hairong, Song Hao, Sun Xiaonan, Song Tiangang, Xie Anming, Xu Jianghua, Qin Ruiying, Jing Lihua, Zuo Taiyang, Zhao Jie, Luan Xiaomei, Wang Zengkun, Chai Huijing, Zhao Yuanzhen, Song Peiji. Reduced radiation dose and volume of contrast medium in heart rate-based, one-stop computed tomography angiography of coronary, carotid and cerebrovascular arteries.. Acta radiologica (Stockholm, Sweden : 1987). 2023. DOI: 10.1177/02841851231193258.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.