MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jvir.2018.05.009

Медицинская библиотека · Journal of vascular and interventional radiology : JVIR · 2018

One-Year Analysis of the Prospective Multicenter SENTRY Clinical Trial: Safety and Effectiveness of the Novate Sentry Bioconvertible Inferior Vena Cava Filter.

Dake Michael D, Murphy Timothy P, Krämer Albrecht H, Darcy Michael D, Sewall Luke E, Curi Michael A, Johnson Matthew S, Arena Frank, Swischuk James L, Ansel Gary M, Silver Mitchell J, Saddekni Souheil, Brower Jayson S, Mendes Robert, SENTRY Trial Investigators

Клиническое исследованиеСтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To prospectively assess the Sentry bioconvertible inferior vena cava (IVC) filter in patients requiring temporary protection against pulmonary embolism (PE).

MATERIALS AND

METHODS

At 23 sites, 129 patients with documented deep vein thrombosis (DVT) or PE, or at temporary risk of developing DVT or PE, unable to use anticoagulation were enrolled. The primary end point was clinical success, including successful filter deployment, freedom from new symptomatic PE through 60 days before filter bioconversion, and 6-month freedom from filter-related complications. Patients were monitored by means of radiography, computerized tomography (CT), and CT venography to assess filtering configuration through 60 days, filter bioconversion, and incidence of PE and filter-related complications through 12 months.

RESULTS

Clinical success was achieved in 111 of 114 evaluable patients (97.4%, 95% confidence interval [CI] 92.5%-99.1%). The rate of freedom from new symptomatic PE through 60 days was 100% (n = 129, 95% CI 97.1%-100.0%), and there were no cases of PE through 12 months for either therapeutic or prophylactic indications. Two patients (1.6%) developed symptomatic caval thrombosis during the first month; neither experienced recurrence after successful interventions. There was no filter tilting, migration, embolization, fracture, or caval perforation by the filter, and no filter-related death through 12 months. Filter bioconversion was successful for 95.7% (110/115) at 6 months and for 96.4% (106/110) at 12 months.

CONCLUSIONS

The Sentry IVC filter provided safe and effective protection against PE, with a high rate of intended bioconversion and a low rate of device-related complications, through 12 months of imaging-intense follow-up.

Для цитирования: Dake Michael D, Murphy Timothy P, Krämer Albrecht H, Darcy Michael D, Sewall Luke E, Curi Michael A, Johnson Matthew S, Arena Frank, Swischuk James L, Ansel Gary M, Silver Mitchell J, Saddekni Souheil, Brower Jayson S, Mendes Robert, SENTRY Trial Investigators. One-Year Analysis of the Prospective Multicenter SENTRY Clinical Trial: Safety and Effectiveness of the Novate Sentry Bioconvertible Inferior Vena Cava Filter.. Journal of vascular and interventional radiology : JVIR. 2018. DOI: 10.1016/j.jvir.2018.05.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.