m+Medelevator.RU
← Поиск публикаций
Journal of AAPOS : the official publication of the American Association for Pediatric Ophthalmology and Strabismus · 2017

Strabismus surgery outcomes in eyes with glaucoma drainage devices.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Osigian Carla J, Cavuoto Kara M, Rossetto Julia D, Sayed Mohamed, Grace Sara, Chang Ta C, Capo Hilda

Аннотация

PURPOSE: To report strabismus surgery outcomes in eyes with prior implantation of glaucoma drainage devices (GDD).

METHODS: The medical records of patients who underwent strabismus surgery for ocular misalignment that developed after implantation of a GDD over a 13-year period at a single institution were examined retrospectively. Patient characteristics, deviation types, preoperative measurements, surgical procedures, and postoperative measurements were analyzed.

RESULTS: Of the 16 patients included, 14 had exotropia (34Δ ± 16Δ) and 11 had vertical deviations (15Δ ± 7Δ), of which 9 had concurrent exotropia and vertical deviations. Preoperatively, 9 patients had diplopia. The surgical approach was tailored to address the deviation most noticeable to the patient-horizontal, vertical, or both if the vertical component could be addressed by horizontal muscle supra- or infraplacement. Three patients underwent simultaneous horizontal and vertical surgery. All patients underwent strabismus surgery on an eye with a GDD. Surgical motor success (defined as horizontal deviation ≤10Δ, vertical ≤4Δ) was achieved in 42% of horizontal and 57% of vertical deviations. Postoperatively 74% of deviations decreased by ≥50% in magnitude. Diplopia resolved in 50% of patients who presented with preoperative diplopia. One patient had intraoperative bleb perforation, but none had postoperative hypotony at any follow-up visit. Only 2 required a second strabismus surgery.

CONCLUSIONS: Strabismus surgery with preservation of the filtering bleb following implantation of a glaucoma drainage device is a low risk procedure that can improve ocular alignment and related symptoms, despite a low motor success rate by standard criteria.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты