Song Zong-Ming, Hu Xu-Ting, Wang Lei, Hu Zhi-Xiang, Zhao Pei-Quan, Chen Ding

Аннотация

AIM: To report a simple approach to actively remove high viscosity silicone oil through a 23-gauge cannula via pars plana.

METHODS: Forty-eight eyes of 48 patients underwent silicone oil (5700 centistokes) removal (SOR) were enrolled. A section of blood transfusion set was prepared to connect a standard 23-gauge cannula and vitrectomy machine. Silicone oil was removed with suction of 500-mm Hg vacuum through the cannula. Main outcome measures were SOR duration, number of sutured sites, intraocular pressure (IOP), best-corrected visual acuity (BCVA), and complications.

RESULTS: Silicone oil was successfully removed in all cases. The mean SOR time was 5.70±0.85min. Nine eyes (18.75%) needed suture partial sclerotomies. No intraoperative complications were noted. Transient hypotony (≤8 mm Hg) was seen in 3 eyes (6.25%) on postoperative day 1, but all resolved within 1wk. Retinal reattachment was achieved in all cases and no other postoperative complications were noted during 3-month following-up. BCVA at the final visit improved or stabilized in all patients comparing to the preoperative level.

CONCLUSION: Active removal of high viscosity silicone oil through a 23-gauge instrument cannula jointed with blood transfusion set is a practical and reliable technique when considering two sides of efficacy and safety.