MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/02841851241269918

Медицинская библиотека · Acta radiologica (Stockholm, Sweden : 1987) · 2024

A new era of high-resolution CT diagnostics of the lung: improved image quality, detailed morphology, and reduced radiation dose with high-resolution photon-counting CT of the lungs compared to high-resolution energy-integrated CT.

Aurumskjöld Marie-Louise, Sjunnesson Lotta, Pistea Adrian, Ásbjörnsson Gylfi, Wellman Fredrik, Bozovic Gracijela

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

High-resolution computed tomography (HRCT) is dependent on detailed morphology in diagnostic assessment of interstitial lung diseases. Photon-counting CT (PCCT) enables improved resolution while reducing radiation.

PURPOSE: To compare if the image quality, detailed morphology, and radiation dose in HRCT of the lung improves with PCCT compared to energy-integrated CT (EICT).

MATERIAL AND

METHODS

HRCT with PCCT in patients with body mass index (BMI) from normal to obese, previously examined with different EICT were included. They were evaluated in a five-step scale for image quality according to Quality Criteria for CT (Diagnostic Requirement of the ImPACT group-European standardization). In addition, ground-glass opacities, bronchiectasis, emphysema, nodules, and subpleural detailed morphology (≤1 cm from the pleural border) were evaluated by three independent thoracic and/or pediatric radiologists. Visual grading characteristics (VGC) were used for comparison of image quality and detailed morphology and Fleiss kappa for intra-observer variability. Dose-length product (DLP) and CT dose index-volume (CTDIvol) were collected to calculate effective radiation dose.

RESULTS

HRCT with PCCT in 52 women and 48 men (mean age=67.2 ± 13.6 years; age range=27-87 years; BMI=26.9 kg/m2; range=18.6-45 kg/m2) previously examined with EICT (mean age=65.3 ± 13.6 years; age range=27-85 years; BMI=27 kg/m2; range=18.9-45 kg/m2) were included. There were significant differences in image quality for all entities in favor of PCCT. The radiation dose was reduced with PCCT by 47% in all, particularly pronounced in obese with 48.5%.

CONCLUSION

Image quality, detailed morphology, and radiation dose, particularly in obese patients, were significantly improved in HRCT with PCCT compared to conventional EICT. The new technique enables visualization of subpleural structures.

Для цитирования: Aurumskjöld Marie-Louise, Sjunnesson Lotta, Pistea Adrian, Ásbjörnsson Gylfi, Wellman Fredrik, Bozovic Gracijela. A new era of high-resolution CT diagnostics of the lung: improved image quality, detailed morphology, and reduced radiation dose with high-resolution photon-counting CT of the lungs compared to high-resolution energy-integrated CT.. Acta radiologica (Stockholm, Sweden : 1987). 2024. DOI: 10.1177/02841851241269918.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.