m+Medelevator.RU
← Поиск публикаций
Heliyon · 2023

Tectonic infarct analysis: A computational tool for automated whole-brain infarct analysis from TTC-stained tissue.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Santo Briana A, Ciecierska Shiau-Sing K, Mousavi Janbeh Sarayi S Mostafa, Jenkins TaJania D, Baig Ammad A, Monteiro Andre, Koenigsknecht Carmon, Pionessa Donald, Gutierrez Liza, King Robert M, Gounis Matthew, Siddiqui Adnan H, Tutino Vincent M

Аннотация

BACKGROUND: Infarct volume measured from 2,3,5-triphenyltetrazolium chloride (TTC)-stained brain slices is critical to in vivo stroke models. In this study, we developed an interactive, tunable, software that automatically computes whole-brain infarct metrics from serial TTC-stained brain sections.

METHODS: Three rat ischemic stroke cohorts were used in this study (Total n = 91 rats; Cohort 1 n = 21, Cohort 2 n = 40, Cohort 3 n = 30). For each, brains were serially-sliced, stained with TTC and scanned on both anterior and posterior sides. Ground truth annotation and infarct morphometric analysis (e.g., brain-Vbrain, infarct-Vinfarct, and non-infarct-Vnon-infarct volumes) were completed by domain experts. We used Cohort 1 for brain and infarct segmentation model development (n = 3 training cases with 36 slices [18 anterior and posterior faces], n = 18 testing cases with 218 slices [109 anterior and posterior faces]), as well as infarct morphometrics automation. The infarct quantification pipeline and pre-trained model were packaged as a standalone software and applied to Cohort 2, an internal validation dataset. Finally, software and model trainability were tested as a use-case with Cohort 3, a dataset from a separate institute.

RESULTS: Both high segmentation and statistically significant quantification performance (correlation between manual and software) were observed across all datasets. Segmentation performance: Cohort 1 brain accuracy = 0.95/f1-score = 0.90, infarct accuracy = 0.96/f1-score = 0.89; Cohort 2 brain accuracy = 0.97/f1-score = 0.90, infarct accuracy = 0.97/f1-score = 0.80; Cohort 3 brain accuracy = 0.96/f1-score = 0.92, infarct accuracy = 0.95/f1-score = 0.82. Infarct quantification (cohort average): Vbrain (ρ = 0.87, p < 0.001), Vinfarct (0.92, p < 0.001), Vnon-infarct (0.80, p < 0.001), %infarct (0.87, p = 0.001), and infarct:non-infact ratio (ρ = 0.92, p < 0.001).

CONCLUSION: Tectonic Infarct Analysis software offers a robust and adaptable approach for rapid TTC-based stroke assessment.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты