MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4067/s0034-98872007000300010

Медицинская библиотека · Revista medica de Chile · 2007

[Percutaneous inferior vena cava filters: indications and results in 287 patients].

Arriagada Ivette, Mertens Renato, Valdés Francisco, Krämer Albrecht, Mariné Leopoldo, Bergoeing Michel, Soto Sebastián, Vergara Jeannette, Valdebenito Magaly

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Anticoagulation is the treatment of choice for deep vein thrombosis (DVT) and pulmonary embolism (PE). Occasionally this treatment is contraindicated or fails to prevent PE. In these patients, inferior vena caval (IVC) interruption is indicated and insertion of a filter is the most commonly performed procedure.

AIM: To report the experience with IVC filters.

MATERIAL AND

METHODS

Retrospective review of all medical records and operative protocols of patients subjected to IVC filter implantations. Follow up was performed by telephone contact with the patient, relatives or primary physicians, ambulatory consultation or by death certificates.

RESULTS

During the period 1993-2005 we implanted IVC filters on 287 patients, 55.4% male, average age: 62.1 yrs (17-99). Indications for the procedure were DVT or PE and contraindication of anticoagulation in 141 patients (49.1%), DVT or PE and complication of anticoagulation in 65 patients (22.6%), prophylaxis in 39 patients (13.6%), massive PE or poor respiratory function in 31 patients (10.8%), paradoxal emboli in 4 patients (1.4%) and other causes in seven patients. All percutaneous devices were successfully inserted. There was no morbidity or mortality related to the procedure. The most frequent access site was the internal jugular vein (66.6%). In 24 patients (8.4%) the filter was intentionally deployed above the renal veins. Six patients (2.1%) were lost to follow up after discharge. A mean follow up of 41.5 months was achieved. Ninety one patients died, with a 5 years survival of 64.7%. Symptomatic recurrent PE occurred in 6 patients (2.1%) and was the cause of death on 3 of them (1%), DVT has been detected in 22 patients (7.7%) during the follow up period.

CONCLUSIONS

IVC filter implantation is a safe and effective short and long term measure to prevent PE and its consequences.

Для цитирования: Arriagada Ivette, Mertens Renato, Valdés Francisco, Krämer Albrecht, Mariné Leopoldo, Bergoeing Michel, Soto Sebastián, Vergara Jeannette, Valdebenito Magaly. [Percutaneous inferior vena cava filters: indications and results in 287 patients].. Revista medica de Chile. 2007. DOI: 10.4067/s0034-98872007000300010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.