American journal of kidney diseases : the official journal of the National Kidney Foundation · 2004
Transjugular kidney biopsy.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Thompson Barbara C, Kingdon Edward, Johnston Malcolm, Tibballs Jonathan, Watkinson Anthony, Jarmulowicz Michael, Burns Aine, Sweny Paul, Wheeler David C
Аннотация
BACKGROUND: Most previous studies demonstrating the feasibility of transjugular kidney biopsy have used a modified Colapinto aspiration biopsy needle. We present 25 high-risk patients, with contraindications to percutaneous renal biopsy, who underwent transjugular kidney biopsy using a transvenous side-cut needle. This technique is easier to learn and can be performed by an interventional radiologist with transjugular liver biopsy experience and equipment. The needle is designed for optimal cortical sampling but has a high incidence of capsular perforation. Elective coil embolization was used in selected patients to reduce the risk of bleeding.
METHODS: We retrospectively reviewed the indications for obtaining renal histology, based on clinical presentation, and the specific indications for transjugular biopsy. Transjugular kidney biopsy was assessed for sampling effectiveness and adequacy, the impact of histology on patient management, and technique complication rates.
RESULTS: Renal tissue was obtained in 23 cases, with diagnostic biopsies in 21 of 23 (91.3%). A mean of 3.5 cores were obtained with 9.9 glomeruli per procedure for light microscopy (range, 0 to 32), 2.2 (range, 1 to 7) for electron microscopy, and adequate tissue for immunoflorescence available in 11 of 23 biopsies. Histology influenced patient management in all 23 cases. Capsular perforation was recorded in 73.9% (17 of 23) of cases with 6 undergoing elective coil embolization. Two major complications occurred, both in patients with multiple risk factors for bleeding. One required coil embolization of an arterio-calyseal system fistula. A further patient developed renal vein thrombosis 6 days after a failed transjugular kidney biopsy.
CONCLUSION: Transjugular kidney biopsy provides a histological diagnosis in high-risk patients, making an important contribution to patient management.
METHODS: We retrospectively reviewed the indications for obtaining renal histology, based on clinical presentation, and the specific indications for transjugular biopsy. Transjugular kidney biopsy was assessed for sampling effectiveness and adequacy, the impact of histology on patient management, and technique complication rates.
RESULTS: Renal tissue was obtained in 23 cases, with diagnostic biopsies in 21 of 23 (91.3%). A mean of 3.5 cores were obtained with 9.9 glomeruli per procedure for light microscopy (range, 0 to 32), 2.2 (range, 1 to 7) for electron microscopy, and adequate tissue for immunoflorescence available in 11 of 23 biopsies. Histology influenced patient management in all 23 cases. Capsular perforation was recorded in 73.9% (17 of 23) of cases with 6 undergoing elective coil embolization. Two major complications occurred, both in patients with multiple risk factors for bleeding. One required coil embolization of an arterio-calyseal system fistula. A further patient developed renal vein thrombosis 6 days after a failed transjugular kidney biopsy.
CONCLUSION: Transjugular kidney biopsy provides a histological diagnosis in high-risk patients, making an important contribution to patient management.