MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/152660280301000525

Медицинская библиотека · Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists · 2003

Percutaneous management of extensive clot trapped in a temporary vena cava filter.

Vrachliotis Thomas G, Tachtaras Athanassios, Doundoulakis Nicholaos, Sheiman Robert G, Papadopoulos Vassilios, Stringaris Kiriakos A

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To present percutaneous management of extensive clot trapped in a temporary inferior vena cava (IVC) filter.

CASE REPORT: A 20-year-old man with a large sacral tumor and left external iliac vein thrombosis had a wire-mounted Günther temporary filter (GTF) prophylactically placed in the infrarenal IVC prior to tumor resection. The 7-day postsurgical venogram prior to filter removal showed extensive clot trapped by the filter, as well as interval cephalic migration, with the filter tip now at the level of the renal veins. A Günther Tulip MReye (GTM) filter was deployed but not released above the renal veins to prevent clot migration during caudal withdrawal of the wire-mounted GTF. After creating enough space in the infrarenal IVC, the GTM was repositioned and fully released with its apex now below the renal veins. The GTF was then uneventfully removed. There was no clinical evidence for significant pulmonary embolism 12 months after placement.

CONCLUSIONS

Cephalic migration of a clotted temporary IVC filter can be managed with intraprocedural protection against pulmonary embolism by first deploying a Günther Tulip filter above the renal veins, with subsequent advancement below the renal veins before temporary filter removal.

Для цитирования: Vrachliotis Thomas G, Tachtaras Athanassios, Doundoulakis Nicholaos, Sheiman Robert G, Papadopoulos Vassilios, Stringaris Kiriakos A. Percutaneous management of extensive clot trapped in a temporary vena cava filter.. Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists. 2003. DOI: 10.1177/152660280301000525.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.