BACKGROUND

The AshSplit catheter has recently been introduced as an alternative permanent tunnelled haemodialysis catheter, combining ease of insertion with good long-term patency and flow rates.

METHODS

Data were collected prospectively on all the long-term tunnelled haemodialysis (AshSplit) catheters inserted radiologically between January 1998 and March 1999. Information was obtained regarding the initial insertion, ongoing catheter function and re-intervention up to September 1999.

RESULTS

A total of 118 catheters were inserted in 88 patients (50 male), median (range) age 64 (20-86) years. Ultrasound guidance was used routinely and the right internal jugular vein was used in 80 (68%) cases. Initial complications occurred in 14 (11.9%) cases, which included local haemorrhage, carotid artery puncture, and air embolism. Infection occurred in 34% of catheters (2.4/1000 catheter days). Line thrombosis was documented in 20% (1.2/1000 catheter days). Satisfactory mean urea reduction ratio (URR) of 63 was obtained for all catheters. There were 47 re-interventions, mainly for fibrin sheath stripping (34) and/or thrombectomy (25). Total catheter duration was 21600 days with a 1 month cumulative survival of 87% (Kaplan-Meier probability 85%). At the end of the study, 20 (17%) catheters were still functioning, 39 (33%) had been removed electively, and 22 (18%) patients had died with a functioning catheter in situ. Catheter infection was implicated in four deaths.

CONCLUSIONS

Radiological insertion of the AshSplit catheter is well tolerated, providing reliable short- and long-term dialysis access. Radiology also has a role in maintaining patency. As with all tunnelled catheters, infection remains a problem.

Для цитирования: Ewing Fiona, Patel Dilip, Petherick Anne, Winney Robin, McBride Kieran. Radiological placement of the AshSplit haemodialysis catheter: a prospective analysis of outcome and complications.. Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association. 2002. DOI: 10.1093/ndt/17.4.614.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.