MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s001470050014

Медицинская библиотека · Transplant international : official journal of the European Society for Organ Transplantation · 2000

Successful endoluminal thrombo-aspiration of renal graft venous thrombosis.

Rerolle J P, Antoine C, Raynaud A, Beyssen B, Julia P, Duboust A, Glotz D

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

Renal transplant vein thrombosis is an unusual event occurring in 0.3-3% of renal transplantations. Prognosis is uniformly poor with graft loss in nearly every case. We report here the first three cases of renal graft vein thrombosis successfully treated by percutaneous endoluminal thromboaspiration. After an initially uneventful course all recipients developed anuria and required hemodialysis. In two cases, an ultrasound examination suggested a diagnosis of venous thrombosis. Emergency arteriography and phlebography were performed, confirming the complete thrombosis of the graft veins. Thromboaspiration was carried out with full heparinization and led to renal function improvement in all cases. Grafts are still functioning 6 months after the procedure, with serum creatinine levels of 176 mumol/l, 120 mumol/l and 184 mumol/l, respectively. Thus, this procedure avoids surgical and anaesthetic risks and allows, if performed at an early stage, restoration of graft function. Great care must be taken to avoid vein wall damage, vascular suture line rupture, or pulmonary embolism.

Для цитирования: Rerolle J P, Antoine C, Raynaud A, Beyssen B, Julia P, Duboust A, Glotz D. Successful endoluminal thrombo-aspiration of renal graft venous thrombosis.. Transplant international : official journal of the European Society for Organ Transplantation. 2000. DOI: 10.1007/s001470050014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.